68 / 94 page TON = TPWM ⋅ DC Equation 29 TPWM is the PWM-period-time (TPWM = 1 / fPWM) and DC corresponds to the duty cycle. This results in: th HS ,meas = TPWM ⋅ DC + tf HS ,total,min − tr HS ,total,max Equation 30 If the measurement should be started in the center of the ADC time window th(HS),meas, the sample delay tsample has to be set to the following: tsample = tr HS ,total,max + th HS ,meas 2 Equation 31 If the ADC measurement time window should be placed right in the center of th(HS),meas for a given ADC conversion time tADC, the sample delay time tsample can be calculated as follows: tsample = tr HS ,total,max + th HS ,meas − tADC 2 Equation 32 This measurement scenario is illustrated in Figure 72. BTN8960 /62 /80 /82 High Current PN Half Bridge Switching Timing Application Note 68 Rev. 0.6 2017-02-21 |
同様の部品番号 - BTN8962 |
|
同様の説明 - BTN8962 |
|
|
リンク URL |
プライバシーポリシー |
ALLDATASHEET.JP |
ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |