  NE555 Datasheet HTML 1Page - NXP Semiconductors NE555 Datasheet HTML 2Page - NXP Semiconductors NE555 Datasheet HTML 3Page - NXP Semiconductors NE555 Datasheet HTML 4Page - NXP Semiconductors NE555 Datasheet HTML 5Page - NXP Semiconductors NE555 Datasheet HTML 6Page - NXP Semiconductors NE555 Datasheet HTML 7Page - NXP Semiconductors  
Zoom Inzoom in Zoom Outzoom out
 7 / 7 page
background image
Philips Semiconductors Linear Products
Product specification
NE/SA/SE555/SE555C
Timer
August 31, 1994
352
TYPICAL APPLICATIONS
DURATION OF
TRIGGER PULSE AS
SEEN BY THE TIMER
VCC
VCC
10k
2
555
.001
µF
NOTE: All resistor values are in
Figure 1. AC Coupling of the Trigger Pulse
1
SWITCH GROUNDED
AT THIS POINT
OVOLTS
1/3 VCC
VCC
Trigger Pulse Width Requirements and Time
Delays
Due to the nature of the trigger circuitry, the timer will trigger on the
negative going edge of the input pulse. For the device to time out
properly, it is necessary that the trigger voltage level be returned to
some voltage greater than one third of the supply before the time out
period. This can be achieved by making either the trigger pulse
sufficiently short or by AC coupling into the trigger. By AC coupling
the trigger, see Figure 1, a short negative going pulse is achieved
when the trigger signal goes to ground. AC coupling is most
frequently used in conjunction with a switch or a signal that goes to
ground which initiates the timing cycle. Should the trigger be held
low, without AC coupling, for a longer duration than the timing cycle
the output will remain in a high state for the duration of the low
trigger signal, without regard to the threshold comparator state. This
is due to the predominance of Q15 on the base of Q16, controlling
the state of the bi-stable flip-flop. When the trigger signal then
returns to a high level, the output will fall immediately. Thus, the
output signal will follow the trigger signal in this case.
Another consideration is the “turn-off time”. This is the measurement
of the amount of time required after the threshold reaches 2/3 VCC
to turn the output low. To explain further, Q1 at the threshold input
turns on after reaching 2/3 VCC, which then turns on Q5, which turns
on Q6. Current from Q6 turns on Q16 which turns Q17 off. This
allows current from Q19 to turn on Q20 and Q24 to given an output
low. These steps cause the 2
µs max. delay as stated in the data
sheet.
Also, a delay comparable to the turn-off time is the trigger release
time. When the trigger is low, Q10 is on and turns on Q11 which turns
on Q15. Q15 turns off Q16 and allows Q17 to turn on. This turns off
current to Q20 and Q24, which results in output high. When the
trigger is released, Q10 and Q11 shut off, Q15 turns off, Q16 turns on
and the circuit then follows the same path and time delay explained
as “turn off time”. This trigger release time is very important in
designing the trigger pulse width so as not to interfere with the
output signal as explained previously.


同様の部品番号 - NE555

メーカー部品番号データシート部品情報
logo
Wing Shing Computer Com...
NE555 WINGS-NE555 Datasheet
273Kb / 5P
   Precision Timer
logo
Diodes Incorporated
NE555 DIODES-NE555 Datasheet
729Kb / 14P
   PRECISION TIMERS
NE555 DIODES-NE555 Datasheet
674Kb / 14P
   Timing from microseconds to hours
February 2021
logo
Fairchild Semiconductor
NE555 FAIRCHILD-NE555 Datasheet
150Kb / 14P
   Single Timer
logo
Unisonic Technologies
NE555 UTC-NE555 Datasheet
205Kb / 8P
   SINGLE TIMER
More results

同様の説明 - NE555

メーカー部品番号データシート部品情報
logo
FOTEK CONTROLS CO., LTD...
TDVN-M3 FOTEK-TDVN-M3 Datasheet
196Kb / 1P
   TWIN TIMER & DEFROSTING TIMER
logo
Festo Corporation.
PZVT-120-SEC FESTO-PZVT-120-SEC Datasheet
83Kb / 1P
   Timer
PZVT-99999-MIN-B FESTO-PZVT-99999-MIN-B Datasheet
84Kb / 1P
   Timer
PZVT-3-SEC FESTO-PZVT-3-SEC Datasheet
83Kb / 1P
   Timer
PZVT-30-SEC FESTO-PZVT-30-SEC Datasheet
83Kb / 1P
   Timer
PZVT-999-SEC-B FESTO-PZVT-999-SEC-B Datasheet
84Kb / 1P
   Timer
logo
Microsemi Corporation
TSC355 MICROSEMI-TSC355 Datasheet
489Kb / 4P
   Timer
logo
National Semiconductor ...
LM555 NSC-LM555 Datasheet
822Kb / 12P
   Timer
logo
Texas Instruments
LM555 TI1-LM555 Datasheet
1Mb / 25P
[Old version datasheet]   Timer
logo
Festo Corporation.
PZVT-300-SEC FESTO-PZVT-300-SEC Datasheet
83Kb / 1P
   Timer
More results


Html Pages

1 2 3 4 5 6 7


データシート ダウンロード

Go To PDF Page


リンク URL




プライバシーポリシー
ALLDATASHEET.JP
ALLDATASHEETはお客様のビジネスに役立ちますか?  [ DONATE ] 

Alldatasheetは   |   広告   |   お問い合わせ   |   プライバシーポリシー   |   リンク交換   |   メーカーリスト
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com