データシートサーチシステム
  Japanese  ▼
ALLDATASHEET.JP

X  

DCE.91.092.BVC データシート(PDF) 192 Page - LEMO Connectors

部品番号 DCE.91.092.BVC
部品情報  unipole and multipole connectors
PDF  204 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
メーカー  LEMO [LEMO Connectors]
ホームページ  https://www.lemo.com/en
Logo LEMO - LEMO Connectors

DCE.91.092.BVC データシート(HTML) 192 Page - LEMO Connectors

Back Button DCE.91.092.BVC Datasheet HTML 188Page - LEMO Connectors DCE.91.092.BVC Datasheet HTML 189Page - LEMO Connectors DCE.91.092.BVC Datasheet HTML 190Page - LEMO Connectors DCE.91.092.BVC Datasheet HTML 191Page - LEMO Connectors DCE.91.092.BVC Datasheet HTML 192Page - LEMO Connectors DCE.91.092.BVC Datasheet HTML 193Page - LEMO Connectors DCE.91.092.BVC Datasheet HTML 194Page - LEMO Connectors DCE.91.092.BVC Datasheet HTML 195Page - LEMO Connectors DCE.91.092.BVC Datasheet HTML 196Page - LEMO Connectors Next Button
Zoom Inzoom in Zoom Outzoom out
 192 / 204 page
background image
®
®
190
www.lemo.com
Test voltage (Ue) :
(measured according to the IEC 60512-2 test 4a standard)
It corresponds to 75% of the mean breakdown voltage.
Test voltage is applied at 500 V/s and the test duration is
1 minute.
This test has been carried out with a mated plug and socket,
with power supply only on the plug end.
The operating voltage value definition is at the entire
responsibility of the customer who defines this value
according to the safety factors that they apply to their
equipment and system.
Caution:
For a number of applications, safety requirements for
electrical appliances are more severe with regard to
operating voltage.
In such cases operating voltage is defined according
to creepage distance and air clearance) between live parts.
Please consult us for the choice of a connector by indi-
cating the safety standard to be met by the product.
Voltage values are given in the table on insulator types for
each series.
They correspond with values measured at sea level. They
are adapted to all applications up to an altitude of 2000 m.
In case a device is used at a higher altitude, air clearance
between live parts has to be multiplied by the following
coefficients.
It means also that test voltage has to be divided by this
coefficient.
Print contacts
straight
elbow
Print contacts are available in straight or elbow versions
for certain connector types, mostly for straight and elbow
socket models. Connection is made on flexible or rigid
printed circuits by soldering.
Straight print contacts are gold-plated which guarantees
optimum soldering, even after long-term storage. However
for wave soldering, we recommend removal the gold-plat-
ing from the contact end on the printed circuit side before
soldering according to the assembly procedures.
Print elbow contacts include a tinned lead free brass wire
crimped into a crimp contact.
(measured according to IEC 60512-3 test 5a)
The specified rated current can be applied simultaneously
to all the contacts.
It corresponds with an average temperature rise of 40°C
of the connector.
The current values are indicated in the table of insulator
types in each series.
For use at higher temperatures acceptable rated current will
be lower. It tends towards zero as the material is used at the
maximum operating temperature accepted for the insulator.
In most case the current depend on the conductor dimension
(see table on page 196) or on the printed circuit dimension.
Caution:
In general, connectors should not be unmated while live.
Test voltage
0
50
25%
50%
75%
100%
100
150
200
250
T (°C)
Rated current
For connectors with PEEK insulator, maximum admissible
current will follow the curve below depending on the oper-
ating temperature T.
Rated current (A)
coefficient
1.00
1.14
1.29
1.48
altitude (m)
2000
3000
4000
5000



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


データシート ダウンロード

Go To PDF Page


リンク URL



ALLDATASHEETはお客様のビジネスに役立ちますか?  [ DONATE ] 

Alldatasheetは   |   広告   |   お問い合わせ   |   プライバシーポリシー   |   データシートへのリンク    |   リンク交換   |   メーカーリスト
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com