ORDERING INFORMATION
xTx(x)4
(x)xxx
x
x
BTE(M):
(m)bar calibration
PTU:
psi calibration
BTE(M)4000 series
001:
0 to 1 bar
N01:
0 to -1 bar
P01:
-1 to +1 bar
002:
0 to 2 bar
005:
0 to 5 bar
010:
0 to 10 bar
0070:
0 to 70 mbar
P070:
-70 to +70 mbar
N250:
0 to -250 mbar
0350:
0 to 350 mbar
N350:
0 to -350 mbar
P350: -350 to +350 mbar
PTU4000 series
001:
0 to 1 psi
P01:
-1 to +1 psi
005:
0 to 5 psi
P05:
-5 to +5 psi
015:
0 to 15 psi
P15:
-15 to +15 psi
030:
0 to 30 psi
100:
0 to 100 psi
150:
0 to 150 psi
Output signal
0:
0...10 V
1:
1...6 V
4:
4...20 mA
7:
0...5 V
Pressure mode
G:
gage pressure1
A:
absolute pressure
(available for pressure ranges
from 1 bar/15 psi upwards only)
Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the
application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
Note:
Other pressure ranges and options are widely available.
Please contact your nearest Sensortechnics sales representative.
Specification notes:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
IP 65 protection is given with locked connector only. The package is an all-sealed housing. For proper function, the gage port
is vented to the atmosphere through the connecting cable. Thus, the cable end must have access to the ambient pressure.
The minimum supply voltage is directly proportional to the load resistance seen by the transmitter. For more details see the
load limitation diagram.
Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element.
Full scale span is the algebraic difference between the positive full scale output and offset.
Thermal effects tested and guaranteed from 0 to 50°C relative to 25°C. All specifications shown are relative to 25°C.
Linearity refers to the Best Straight Line fit measured for offset pressure, full scale pressure and 1/2 full scale pressure.
Long term stability is the change in output after one year or 1 million pressure cycles.
Test are in accordance with EN61000-6-2, April 1999.
CE-labelling is in accordance with 89/336/EEC.
The pressure transmitters must not be used as safety accessories according to article 1, 2.1.3 of the directive 97/23/EC.