F2VF-AZ-R
AI

The **F2VF-AZ-R** is an automotive-grade power relay manufactured by **Fujitsu**. It is part of the F2 series, specifically designed for high-current applications within vehicle systems, such as engine control, power steering, and lighting modules.
---
### 1. Key Technical Specifications
The following table outlines the core electronic and mechanical parameters of the F2VF-AZ-R:
| Parameter | Specification |
| :--- | :--- |
| **Contact Arrangement** | 1 Form A (SPST-NO) |
| **Nominal Coil Voltage** | 12V DC |
| **Switching Current (Max)** | 35A (Continuous) / 100A (Inrush) |
| **Coil Resistance** | ~114 Ω |
| **Operating Temperature** | -40°C to +125°C |
| **Contact Material** | Silver Tin Oxide (AgSnO2) |
| **Mounting Type** | PCB (Through-hole) |
---
### 2. Major Electronic Components & Construction
#### A. The Coil System
The heart of the relay is an electromagnetic coil. When a 12V signal is applied, it generates a magnetic field that moves the armature. The "AZ" designation often refers to a specific coil sensitivity or high-temperature insulation class suitable for under-the-hood environments.
#### B. Contact System (Silver Tin Oxide)
The contacts are made of **AgSnO2**. This material is used because:
* It resists "welding" during high inrush currents.
* It provides high reliability over thousands of switching cycles.
* It handles the heat generated by 35A continuous loads without significant degradation.
#### C. Environmental Sealing
The **"-R"** suffix typically denotes a "flux-tight" or plastic-sealed construction. This prevents solder flux or environmental contaminants (like moisture and dust) from entering the relay housing during the manufacturing process or during the vehicle's lifespan.
---
### 3. Common Applications
Due to its high current handling and compact PCB footprint, it is frequently found in:
* **ABS Control Units:** Managing pump motors.
* **Power Windows & Seats:** Controlling bidirectional motors.
* **Cooling Fans:** Switching high-power radiator fan motors.
* **HID/LED Lighting:** Managing the initial high-voltage surge.
---
- ⤷
What is the difference between the F2VF and the standard F2 series?
- ⤷ Can this relay be used in 24V truck applications?
- ⤷ What are the PCB layout requirements for handling 35A with this relay?