M2RTS-R-D4-R2/N
AI

The **M2RTS-R-D4-R2/N** is a specific model of a **Resistance Thermometer Transmitter** (RTD Transmitter) from the M2-Series, typically manufactured by **M-System**. This device is used in industrial automation to convert a temperature signal from an RTD sensor into a standard analog signal for a PLC or controller.
---
### ## Technical Specifications Breakdown
The model number can be decoded based on the manufacturer’s nomenclature:
| Component Code | Specification Detail | Description |
| :--- | :--- | :--- |
| **M2RTS** | Model Series | RTD Transmitter (Plug-in type) |
| **R** | Input Type | RTD (e.g., Pt 100, JPt 100) |
| **D4** | Output Signal | 4 – 20 mA DC (Current Loop) |
| **R2** | Power Input | 100 – 240V AC |
| **N** | Standards/Options | Typically denotes "None" or standard compliance (CE/UL depending on context) |
---
### ## Key Electronic Components & Functions
The internal circuitry of this transmitter consists of several functional blocks:
1. **Input Conditioning (Bridge Circuit):**
* The unit uses a constant current source to drive the RTD.
* It measures the voltage drop across the RTD sensor to calculate resistance.
* It includes **leadwire resistance compensation** (3-wire system) to ensure accuracy over long cable runs.
2. **Signal Isolation (Galvanic Isolation):**
* This model features **three-way isolation** (Input to Output to Power).
* This prevents ground loops and protects the control system from high-voltage surges on the field side.
3. **Linearizer:**
* RTD resistance-temperature curves are not perfectly linear. The internal electronics include a linearizing circuit to ensure the 4-20mA output is directly proportional to the temperature, not the resistance.
4. **Zero & Span Adjustments:**
* Located on the front panel, these potentiometers allow for fine-tuning the calibration of the minimum (4mA) and maximum (20mA) points.
---
### ## Wiring Terminal Configuration
Typical wiring for the M2-Series base socket:
| Terminal No. | Function | Connection |
| :--- | :--- | :--- |
| **1** | Output (+) | 4-20mA Signal to PLC |
| **2** | Output (-) | Signal Ground |
| **3** | Input (A) | RTD Lead A |
| **4** | Input (B) | RTD Lead B |
| **5** | Input (b) | RTD Lead b (Compensation) |
| **7** | Power (U) | 100-240V AC (Live) |
| **8** | Power (V) | 100-240V AC (Neutral) |
---
### ## Diagnostic Indicators
* **Power LED:** Indicates the internal DC power supply is healthy.
* **Burnout Protection:** The electronics are designed to drive the output to a specific state (Upscale >20mA or Downscale <4mA) if the RTD wire breaks, alerting the control system to a sensor failure.
- ⤷
How do I calibrate the Zero and Span for this specific transmitter?
- ⤷ What is the maximum load resistance supported by the 4-20mA output?
- ⤷ Can this unit be used with a 2-wire RTD configuration?