2 / 5 page ![]() Rev B PSLS01 SERIES 1 Watt AC/DC Converter Single Output 1/9/2018 Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797 website: www.wallindustries.com • e-mail: sales@wallindustries.com Page 2 of 5 SPECIFICATIONS All specifications are based on 25°C, Humidity <75%, Nominal Input Voltage, and Rated Output Current unless otherwise noted. We reserve the right to change specifications based on technological advances. SPECIFICATION TEST CONDITIONS Min Typ Max Unit GENERAL SPECIFICATIONS Efficiency 230VAC, %Typ. See Table Switching Frequency 100 kHz Isolation Voltage Input to Output, Test Time: 1 min 3000 VAC PHYSICAL SPECIFICATIONS Weight 0.21oz (6g) Typ. Dimensions (L x W x H) Standard 1.38in x 0.66in x 0.43in (35mm x 16.45mm x 11mm) 90º Bend Pin Package 1.38in x 0.71in x 0.43in (35mm x 18mm x 0.11mm) Cooling Free Air Convection SAFETY CHARACTERISTICS Safety Standards & Certification IEC60950, EN60950, UL60950 Safety Class Class II EMI CE CISPR32/EN55032 CIRSP32/EN55032 Class A(3) Class B(4) RE CISPR32/EN55032 CISPR32/EN55032 Class A(3) Class B(4 ESD IEC/EN61000-4-2 ±4kV Pref. Criteria B RS IEC/EN61000-4-3 10V/m(4) Perf. Criteria A EFT IEC/EN61000-4-4 IEC/EN61000-4-4 ±2kV(3) ±4kV(4) Perf. Criteria B Perf. Criteria B Surge IEC/EN61000-4-5 Line to Line ±1kV(3) Perf. Criteria B IEC/EN61000-4-5 Line to Line ±1kV/line to ground ±2kV(4) Perf. Criteria B CS IEC/EN61000-4-6 10Vr.m.s(4) Perf. Criteria A Voltage Dips, Short Interruption, and Voltage Variations Immunity IEC/EN61000-4-11 0%-70%(4) Perf. Criteria B NOTES 1. 90 degree SIP package is available for each model in this series. To indicate 90 degree package, add “-F” to model number. Ex. PSLS01-15B05SS-F. 2. Ripple and noise are measured by “parallel cable” method. 3. See Fig. 1 for recommended circuit. 4. See Fig. 2 for recommended circuit. 5. External electrolytic capacitors are required to modules, for more info refer to typical applications 6. In order to increase conversion efficiency of the product with light load in the design, product will have audio noise when it is operating, but will not affect the product’s reliability and performance 7. Module required dispensing fixed after assembled. 8. This part is open frame, at least 6.4mm safety distance between primary and secondary external components of module is needed to meet safety requirements. 9. Product customization is available. *Due to advances in technology, specifications subject to change without notice. CHARACTERISTIC CURVES Temperature Derating Graph Input Voltage Derating Graph Note: This product is suitable for use in natural air cooling envirionments. If in a closed environment, please contact factory. |
|
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |