| データシートサーチシステム |
|
PSLS05 データシート(PDF) 2 Page - Wall Industries,Inc. |
|
|
|||||||||||||||||||||||||||||
PSLS05 データシート(HTML) 2 Page - Wall Industries,Inc. |
|
2 / 6 page ![]() Rev B PSLS05 SERIES Up to 5 Watts AC/DC Converter Single Output 1/9/2018 Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797 website: www.wallindustries.com • e-mail: sales@wallindustries.com Page 2 of 6 SPECIFICATIONS All specifications are based on 25°C, Humidity <75%, Nominal Input Voltage, and Rated Output Current unless otherwise noted. We reserve the right to change specifications based on technological advances. SPECIFICATION TEST CONDITIONS Min Typ Max Unit ENVIRONMENTAL SPECIFICATIONS Operating Temperature -25 +85 ºC Storage Temperature -40 +105 ºC Storage Humidity 85 %RH Welding Temperature Wave-Soldering 260±5ºC; time: 5~10s Manual-Welding 360±10ºC; time:3~5s Power Derating -25ºC~0ºC 0.8 %/ºC +55ºC~+85ºC 1.33 MTBF MIL-HDBK-217F @25ºC 300,000 Hours GENERAL SPECIFICATIONS Efficiency 230VAC, % typ. See Table Switching Frequency 100 kHz Isolation Voltage Input to Output (Test Time: 1min (leakage current setting value: 5mA) 3000 VAC PHYSICAL SPECIFICATIONS Weight 0.25oz (7g) Dimensions (L x W x H) Standard Pins 1.65in x 0.73in x 0.54in (42mm x 18.50mm x 13.65mm) -F Suffix 1.65in x 0.79in x 0.55in (42mm x 20mm x 14mm) Cooling Free Air Convection SAFETY CHARACTERISTICS Safety Approvals & Regulated Certification IEC60950 EN60950 UL60950 Certifications Standard Pin Models Only UL, CE, CB Safety Class Class II EMI CE CISPR22/EN55022(2) CISPR22/EN55022(3) Class A Class B RE CISPR22/EN55022(2) (3) Class B ESD IEC/EN61000-4-2 Contact ±4kV Perf. Criteria B RS IEC/EN61000-4-3 10V/m Perf. Criteria A EFT IEC/EN61000-4-4 ±2kV(2) Perf. Criteria B IEC/EN61000-4-4 ±4kV(3) Perf. Criteria B Surge IEC/EN61000-4-5 Line to Line ±1kV(2) Perf. Criteria B IEC/EN61000-4-5 Line to Line ±1kV/line to ground ±2KV (3) Perf. Criteria B CS IEC/EN61000-4-6 3Vr.m.s.(3) Perf. Criteria A PFM IEC/EN61000-4-8 10A/m Perf. Criteria A Voltage Dips, Short Interruptions, Voltage Variations Immunity IEC/EN61000-4-11 0%-70% Perf. Criteria B NOTES 1. Add -F to model name to indicate 90º bent pin model. 2. See Fig. 1 for recommended circuit. 3. See Fig. 2 for recommended circuit 4. Module required dispensing fixed after assembled. 5. This part is open frame, at least 6.4mm safety distance between the primary and secondary external components of the module is needed to meet the safety requirements. 6. Customization is available. *Due to advances in technology, specifications subject to change without notice. |
|
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |