| データシートサーチシステム |
|
MAS6505 データシート(PDF) 19 Page - Micro Analog systems |
|
|
|||||||||||||||||||||||||||||
MAS6505 データシート(HTML) 19 Page - Micro Analog systems |
|
19 / 44 page ![]() DA6505.005 11 June 2018 19 (44) CONTROL REGISTER (EF/6FHEX) The Control register (EF/6FHEX) contains measurement and operating mode selection settings. Writing to Control register starts the selected measurements. See table 4. There are oversampling ratio (OSR) settings for temperature and pressure. The OSRT setting is for temperature and OSRP for pressure measurement. Each of them has seven settings 1/4x, 1/2x, 1x, 2x, 4x, 8x and 16x in addition to no measurement setting. Thus it is possible select only temperature or pressure measurement or both measurements. The oversampling ratio setting affects measurement resolution and speed and power consumption. The highest value setting gives the highest resolution but it has the longest A/D conversion time and the highest power consumption. Similar way the lowest value setting gives the lowest resolution but it has the shortest A/D conversion time and the lowest power consumption. Thus the multiple oversampling ratio settings allow optimizing measurements between speed, power consumption and resolution. See ELECTRICAL CHARACTERISTICS on pages 3-7. The MODE bits select from three operating modes. The MODE=00 setting selects sleep mode in which there are no measurements performed and only a very small sleep current is drawn from the supplies. The MODE=01 or 10 setting selects forced mode which runs selected measurements only once after which the device returns automatically to the sleep mode. The MODE=11 setting selects normal mode in which selected measurements are performed automatically in a loop. The delay between measurements is configured by DELAY bit setting in the Configuration register (EE/6EHEX). To minimize current consumption the device enters standby mode for the time between measurements during which only the internal clock oscillator is running. The automatic measurements are stopped by setting MODE=00 which selects the sleep mode. Table 4. Control register (EF/6FHEX) description Bit Number Bit Name Description Value Function 7-5 OSRT Oversampling ratio for temperature measurement 000 001 010 011 100 101 110 111 No temperature measurement (default) 1/4x Very fast mode 1/2x Fast mode 1x Ultra low power 2x Low power 4x Standard resolution 8x High resolution 16x Ultra high resolution 4-2 OSRP Oversampling ratio for pressure measurement 000 001 010 011 100 101 110 111 No pressure measurement (default) 1/4x Very fast mode 1/2x Fast mode 1x Ultra low power 2x Low power 4x Standard resolution 8x High resolution 16x Ultra high resolution 1-0 MODE Operating mode 00 01, 10 11 Sleep mode (default) Forced mode (single command based measurement) Normal mode (automated measurements) |
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |