| データシートサーチシステム |
|
DRDN40 データシート(PDF) 2 Page - Mean Well Enterprises Co., Ltd. |
|
|
|||||||||||||||||||||||||||||
DRDN40 データシート(HTML) 2 Page - Mean Well Enterprises Co., Ltd. |
|
2 / 5 page ![]() SPECIFICATION DRDN40 MODEL DC VOLTAGE RANGE RATED CURRENT VOLTAGE DROP (Vin-Vout) (max.) INPUT EFFICIENCY (Typ.) OUTPUT SAFETY STANDARDS WORKING TEMP. Note.2 WORKING HUMIDITY STORAGE TEMP. TEMP. COEFFICIENT VIBRATION MTBF DIMENSION OTHERS NOTE PACKING OVERLOAD -40 ~ +80 (Refer to "Derating Curve") ℃ 5 ~ 95% RH non-condensing -40 ~ +85 ℃ ±℃ ℃ 0.03%/ (0 ~ 60 ) Component:10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC61373 557.52K hrs min. Telcordia SR-332 (Bellcore) ; 277.24K hrs min. MIL-HDBK-217F (25 ) ℃ 55*125.2*100mm (W*H*D) 0.5Kg;20psc/11Kg/1.49CUFT WITHSTAND VOLTAGE ISOLATION RESISTANCE IP/OP - Chassis, IP/OP- Relay, Relay - Chassis:>100M Ohms / 500Vdc / 25 / 70% RH ℃ ENVIRONMENT SAFETY & EMC (Note.4) PROTECTION 1. All parameters NOT specially mentioned are measured at normal input(12V/24V/48V) , rated load and 25 of ambient temperature. ℃ 2. Derating may be needed over high ambient temperature. Please check the derating curve for more details. 3. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude ℃℃ higher than 2000m(6500ft). 4. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) PEAK CURRENT FUNCTION Green LED OK RATED CURRENT DC NORMAL VOLTAGE SHORT CIRCUIT PEAK CURRENT (max.) INPUT REVERSE CURRENT (max.) INPUT REVERSE VOLTAGE (max.) Parameter Parameter ESD Radiated EFT / Burst Surge Conducted Magnetic Field Conducted Radiated Harmonic Current Standard Standard EN55032(CISPR32) EN55032(CISPR32) EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 EN61000-4-8 Test Level / Note Test Level / Note Class B Class B ----- EMC IMMUNITY EMC EMISSION EN55035, EN61000-6-2(EN50082-2), EN55024 Level 4, 15KV air ; Level 3, 8KV contact; criteria A Level 3, 10V/m ; criteria A Level 4, 30A/m ; criteria A Level 3, 10V ; criteria A Level 3, 2KV ; criteria A DRDN40- 98% 0~20A x2 input , 0~40A x1 input 0.3V Voltage Flicker IP/OP - Chassis : 0.5KVac IP/OP- Relay : 0.5KVac Relay - Chassis : 0.5KVac ;; File Name:DRDN40-SPEC 2019-08-19 <60A,5Sec. No damage ----- ----- Level 3, 1KV/Line-Line ;Level 3, 2KV/Line-Line-Chassis ;criteria A OPERATING ALTITUDE Note.3 0~40A, 60A, <60A,5Sec. No damage LED STATUS DISPLAY REDUNDANCY For 1+1 redundancy ,and support N+1 redundancy IEC62368-1, UL62368-1, approved EAC TP TC 004 NUMBER OF INPUT 2 Channels Continuous 5Sec. Continuous 5Sec. CAPACITANCE(Typ.) 320uF STANDBY POWER LOSSES(Typ.) 1.5W COOLING Free air convection 0~30A x2 input , 0~60A x1 input 1mA RELAY 30Vdc/1A resistive load 40Vdc BOTH INPUTS VOLTAGE ALARM <8.5V or >14 7V ( 5 ) .% ± <18V or >31V ( 5 ) % ± <34.2V or >63V ( 5 ) % ± 19~29Vdc 12Vdc 24Vdc 48Vdc 9~14Vdc 36~60Vdc 40Vdc 65Vdc =12V, 24V, 48V 5000 meters/OVC II 40A DIN Rail Type Redundancy Module ----- |
|
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |