| データシートサーチシステム |
|
MPXM2010GS データシート(PDF) 4 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
MPXM2010GS データシート(HTML) 4 Page - NXP Semiconductors |
|
4 / 17 page ![]() MPX2010 Sensors 4 Freescale Semiconductor Pressure On-Chip Temperature Compensation and Calibration Figure 2. shows the output characteristics of the MPX2010 series at 25 °C. The output is directly proportional to the differential pressure and is essentially a straight line. The effects of temperature on full scale span and offset are very small and are shown under Operating Characteristics. This performance over temperature is achieved by having both the shear stress strain gauge and the thin-film resistor circuitry on the same silicon diaphragm. Each chip is dynamically laser trimmed for precise span and offset calibration and temperature compensation. Figure 3. illustrates the differential/gauge die in the basic chip carrier (Case 344). A silicone gel isolates the die surface and wire bonds from the environment, while allowing the pressure signal to be transmitted to the silicon diaphragm. The MPX2010 series pressure sensor operating characteristics and internal reliability and qualification tests are based on use of dry air as the pressure media. Media other than dry air may have adverse effects on sensor performance and long term reliability. Contact the factory for information regarding media compatibility in your application. LINEARITY Linearity refers to how well a transducer's output follows the equation: Vout = Voff + sensitivity x P over the operating pressure range. There are two basic methods for calculating nonlinearity: (1) end point straight line fit (see Figure 4.) or (2) a least squares best line fit. While a least squares fit gives the “best case” linearity error (lower numerical value), the calculations required are burdensome. Conversely, an end point fit will give the “worst case” error (often more desirable in error budget calculations) and the calculations are more straightforward for the user. Freescale’s specified pressure sensor linearities are based on the end point straight line method measured at the midrange pressure. Figure 2. Output vs. Pressure Differential Figure 3. Unibody Package: Cross Sectional Diagram (not to scale) Figure 4. Linearity Specification Comparison Offset (Typical) kPa PSI 2.5 0.362 5 0.725 7.5 1.09 10 1.45 Span Range (Typical) VS = 10 Vdc TA = 25°C P1 > P2 30 25 20 15 10 5 0 – 5 TYP aMAX MIN Silicone Die Coat Die P1 P2 Wire Bond Lead Frame RTV Die Bond Epoxy Case Stainless Steel Metal Cover Least Square Deviation Pressure (% Full Scale) 0 50 100 End Point Straight Line Fit Exaggerated Performance Curve Least Squares Fit Offset Straight Line Deviation |
|
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |