| データシートサーチシステム |
|
ZC05 データシート(PDF) 6 Page - Zhengzhou Winsen Electronics Technology Co., Ltd. |
|
|
|||||||||||||||||||||||||||||
ZC05 データシート(HTML) 6 Page - Zhengzhou Winsen Electronics Technology Co., Ltd. |
|
6 / 7 page ![]() Zhengzhou Winsen Electronics Technology Co., Ltd www.winsen-sensor.com Tel: 86-371-67169097/67169670 Fax: 86-371-60932988 Email: sales@winsensor.com Leading gas sensing solutions supplier in China! Installation instruction This module connects with external part by adopting Pin1.25mm*8 single-row inserting pin, there are four holes with 2mm diameters at the four corners, users fix the module through locations holes and make connection through Pin1.25mm*8 wire. Cautions 1 .Following conditions must be prohibited 1.1 Exposed to organic silicon steam Sensing material will lose sensitivity and never recover if the sensor absorbs organic silicon steam. Sensors must avoid exposing to silicon bond, fixature, silicon latex, putty or plastic contain silicon environment. 1.2 High Corrosive gas If the sensors are exposed to high concentration corrosive gas (such as H 2S, SOX, Cl2, HCl etc.), it will not only result in corrosion of sensors structure, also it cause sincere sensitivity attenuation. 1.3 Touch water Sensitivity of the sensors will be reduced when spattered or dipped in water. 1.4 Freezing Do avoid icing on sensor’s surface, otherwise sensing material will be broken and lost sensitivity. 2 . Following conditions must be avoided 2.1 Water Condensation Indoor conditions, slight water condensation will influence sensors’ performance lightly. However, if water condensation on sensors surface and keep a certain period, sensors’ sensitive will be decreased. 2.2 Used in high gas concentration No matter the sensor is electrified or not, if it is placed in high gas concentration for long time, sensors characteristic will be affected. If lighter gas sprays the sensor, it will cause extremely damage. 2.3 Long time storage The sensors resistance will drift reversibly if it’s stored for long time without electrify, this drift is related with storage conditions. Sensors should be stored in airproof bag without volatile silicon compound. For the sensors with long time storage but no electrify, they need long galvanical aging time for stability before using. The suggested aging time as follow: Stable9. Storage Time Suggested aging time Less than one month No less than 48 hours 1 ~ 6 months No less than 72 hours More than six months No less than 168 hours 2.4 Long time exposed to adverse environment |
|
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |