| データシートサーチシステム |
|
ADMV1009AEZ-R7 データシート(PDF) 5 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADMV1009AEZ-R7 データシート(HTML) 5 Page - Analog Devices |
|
5 / 23 page ![]() Data Sheet ADMV1009 Rev. B | Page 5 of 23 PIN CONFIGURATION AND FUNCTION DESCRIPTIONS 24 NIC 23 NIC 22 NIC 21 NIC 20 NIC 19 LOIN 18 GND 17 NIC 1 2 3 4 5 6 7 8 NIC PIN1 INDICATOR GND RFOUT NIC NIC NIC VGRF NIC TOP VIEW (Not to Scale) ADMV1009 NOTES 1. NIC = NOT INTERNALLY CONNECTED. IT IS RECOMMENDED TO GROUND THESE PINS ON THE PCB. 2. EXPOSED PAD. EXPOSED PAD MUST BE CONNECTED TO GND. GOOD RF AND THERMAL GROUNDING IS RECOMMENDED. Figure 2. Pin Configuration Table 4. Pin Function Descriptions Pin No. Mnemonic Description 1, 4 to 6, 8, 9, 12, 13, 16, 17, 20 to 25, 28, 30, 32 NIC Not Internally Connected. It is recommended to ground these pins on the PCB. 2, 10, 15, 18 GND Ground. These pins are grounded internally and must also be grounded on the PCB. 3 RFOUT RF Output. This pin is ac-coupled internally and matched to 50 Ω, single-ended. 7 VGRF Power Supply Voltage for the Gate of the RF Amplifier. Refer to the Applications Information section for the required external components and biasing. 11, 14 IF2, IF1 Differential IF Inputs. These pins are matched to 50 Ω and are ac-coupled. No external dc block is required. 19 LOIN Local Oscillator Input. This pin is ac-coupled and matched to 50 Ω. 26 VGLO Power Supply Voltage for the Gate of the LO Amplifier. Refer to the Applications Information section for the required external components and biasing. 27 VDLO Power Supply Voltage for the LO Amplifier. Refer to the Applications Information section for the required external components and biasing. 29 VGMIX Power Supply Voltage for the Mixer. This pin is a high impedance port. Refer to the Applications Information section for the required external components and biasing. 31 VDRF Power Supply Voltage for the RF Amplifier. Refer to the Applications Information section for the required external components and biasing. EPAD Exposed pad. The exposed pad must be connected to GND. Good RF and thermal grounding is recommended. |
|
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |