| データシートサーチシステム |
|
MAT3 データシート(PDF) 1 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
MAT3 データシート(HTML) 1 Page - M-System Co.,Ltd. |
|
1 / 5 page ![]() MODEL: MAT3 MAT3 SPECIFICATIONS ES-8164 Rev.3 Page 1/5 http://www.m-system.co.jp/ Lightning Surge Protectors for Electronics Equipment M-RESTER LIGHTNING SURGE PROTECTOR FOR THREE-PHASE POWER SUPPLY Functions & Features • Connected in parallel between the power and earth lines regardless of load current • Applicable to single phase 2/3-wire and threephase 3/4- wire system • High discharge current capacity 20 kA or 40 kA (8/20 μs) • Degraded head element is automatically separated from the power lines by the incorporated thermal breaker, and the LED lamp (turns off) and the relay contact alerts the failure status. • Complies with IEC 61643-11 Class II Typical Applications • Low-voltage distribution board • Combination with installation for large load current 50 (1.97) mm (inch) 98 (3.86) 60 (2.36) MODEL: MAT3–240[1]M[2] ORDERING INFORMATION • Code number: MAT3-240[1]M[2] Specify a code from below for each of [1] and [2]. (e.g. MAT3-2403MY) OPERATIONAL VOLTAGE 240: 240 V AC [1] POWER SYSTEM 3: Single-phase 2/3-wire, Three-phase 3-wire 4: Single-phase 2/3-wire, Three-phase 3/4-wire MAXIMUM DISCHARGE CURRENT M: 20kA (8/20 μsec.) [2] ALARM OUTPUT A: With Y: Without GENERAL SPECIFICATIONS Construction: Standalone; terminal access at the front Degree of protection: IP20 (If the solderless terminals are covered with insulation tubes.) Surge protection type: Voltage limiting type one-port SPD Connection Line: M5 screw terminal (torque: 2.5 N·m) Alarm output: Tension clamp Applicable wire size Line: See the drawing below. Alarm output: 0.13 to 1.5 mm2, stripped length 8 mm Screw terminal Line: Nickel-plated steel Alarm output: Tin-plated copper alloy Housing material: Flame-resistant resin (black) Alarm output: SPDT relay contact trips when the thermal breaker operates. OUTPUT TERMINAL A1 – C Normal: Open Failure or power off: Close OUTPUT TERMINAL A2 – C Normal: Close Failure or power off: Open Rated load: 250 V AC @1 A (resistive load) 24 V DC @1 A (resistive load) Safety function: Thermal breaker incorporated Monitor LED: Green LED turns on during normal condition and turns off during failure condition, power off or the thermal breaker operating. F d : M5 use B ≤ 13.0 mm F ≥ 7.0 mm (F ≥ 8.2 mm for sharing terminals) T ≤ 1.8 mm • Applicable Solderless Terminal Size diameter d INSTALLATION Operating temperature: -5 to +55°C (23 to 131°F) Operating humidity: 5 to 95 %RH (non-condensing) Mounting: DIN Rail Weight: 300 g (0.66 lb) |
同様の部品番号 - MAT3 |
|
同様の説明 - MAT3 |
|
|
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |