データシートサーチシステム
  Japanese  ▼
ALLDATASHEET.JP

X  

R3-DAC16AS/Q データシート(PDF) 2 Page - M-System Co.,Ltd.

部品番号 R3-DAC16AS/Q
部品情報  Remote I/O R3 Series DISCRETE INPUT OUTPUT MODULE
PDF  7 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
メーカー  MSYSTEM [M-System Co.,Ltd.]
ホームページ  https://www.m-system.co.jp/
Logo MSYSTEM - M-System Co.,Ltd.

R3-DAC16AS/Q データシート(HTML) 2 Page - M-System Co.,Ltd.

  R3-DAC16AS/Q Datasheet HTML 1Page - M-System Co.,Ltd. R3-DAC16AS/Q Datasheet HTML 2Page - M-System Co.,Ltd. R3-DAC16AS/Q Datasheet HTML 3Page - M-System Co.,Ltd. R3-DAC16AS/Q Datasheet HTML 4Page - M-System Co.,Ltd. R3-DAC16AS/Q Datasheet HTML 5Page - M-System Co.,Ltd. R3-DAC16AS/Q Datasheet HTML 6Page - M-System Co.,Ltd. R3-DAC16AS/Q Datasheet HTML 7Page - M-System Co.,Ltd.  
Zoom Inzoom in Zoom Outzoom out
 2 / 7 page
background image
MODEL: R3-DAC16A
R3-DAC16A SPECIFICATIONS
ES-8342 Rev.3 Page 2/7
http://www.m-system.co.jp/
Sensing: 24 V DC +10 %
ON current/resistance: ≥ 2.5 mA, ≤ 5.5 kΩ
OFF current/resistance: ≤ 1.5 mA, ≥ 7 kΩ
Detection levels
ON: ≥ 15 V
OFF: ≤ 9 V
OUTPUT SPECIFICATIONS
Output: Wet contact, 8 points
Common: All 8 points (4 terminals, common with the input)
Output voltage: 24 V DC±10 %
Max. load current: 150 mA per point, common
Load resistance: 160 Ω min.
INSTALLATION
Operating temperature: -10 to +55°C (14 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Atmosphere: No corrosive gas or heavy dust
Mounting: Installation Base (model: R3-BSx)
Weight: 200 g (0.44 lb)
PERFORMANCE
Output ON time accuracy: Greater between ±5 % of max.
time or ±0.1 sec. setting
Data allocation: 1
Current consumption: 350 mA
Response time: ≤ 0.1 sec. (delay)
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 1500 V AC @ 1 minute (I/O to internal
bus or internal power)
2000 V AC @ 1 minute (internal power to FG; isolated on the
power supply module)
FUNCTIONS
■OUTPUT HOLD or OUTPUT OFF
In normal conditions, the module outputs the signal from
the preferred bus A.
When an error is detected, the output is switched to the
data from the bus B.
•Output Hold
If both are in error, the module holds the signal and stands
by until one of the communications recovers.
•Output OFF
If both are in error, the module outputs OFF signals and
stands by until one of the communications recovers.
At the startup, it outputs OFF until the communication is
established and normal data is received.
■ MAX. ON POINTS AT ONCE
Function available for One-Shot Output Mode and ON/OFF
Control Output Mode.
Divide the points to be ON at once. When the total of load
current exceeds the maximum load current, "Max. ON
Points at Once" function is activated.
The number of the channel turned ON is output in order
from the lowest.
Example: Max. ON Points at Once: 1 point; One-shot ON
Time setting: 1 sec.
Ch1, 2, 4, 8 all ON: Ch1→Ch2→Ch4→Ch8 are turned ON in
this order in a total time of 4 seconds.
Note: When writing in the same channel two or more times,
check the previous output completion status to set the
output.
Ch1
4sec.
1sec.
Ch2
Ch4
Ch8



Html Pages

1 2 3 4 5 6 7


データシート ダウンロード

Go To PDF Page


リンク URL



ALLDATASHEETはお客様のビジネスに役立ちますか?  [ DONATE ] 

Alldatasheetは   |   広告   |   お問い合わせ   |   プライバシーポリシー   |   データシートへのリンク    |   リンク交換   |   メーカーリスト
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com