| データシートサーチシステム |
|
R3-GC1S/Q データシート(PDF) 4 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
R3-GC1S/Q データシート(HTML) 4 Page - M-System Co.,Ltd. |
|
4 / 6 page ![]() MODEL: R3-GC1 R3-GC1 SPECIFICATIONS ES-8462 Rev.7 Page 4/6 https://www.m-system.co.jp/ TRANSMISSION DATA DESCRIPTIONS 1 2 3 4 5 6 7 8 R3- SV4 R3-BS08 R3- GC1 R3- NE1 R3- PS1 0 15 RWrn+0 Module 1 +15 +31 0 F 0 15 E D C B A 9 8 7 6 5 4 3 2 1 RX(n+0) Unused Module Status Reserved Bits RX(n+7) +16*m–1 • The available data area for R3-GC1 is [16*m] (m=expanded cyclic setting) CC-Link Ver.1.10 0 F 0 15 E D C B A 9 8 7 6 5 4 3 2 1 RX(n+0) Unused Module Status Reserved Bits RX(n+m*7–1) CC-Link Ver.2.00 0 15 RWwn+0 +15 +31 +16*m–1 Module 1 Module 2 Module 2 Module m Module m SLOT REAL MODULE VERTUAL MODULE NO. OF WORDS Slot No.1 R3-SV4 R3-SV4 4 Words Slot No.2 R3-GC1 R3-GC1 (1/4) 16 Words Slot No.3 No module R3-GC1 (2/4) 16 Words Slot No.4 No module R3-GC1 (3/4) 16 Words Slot No.5 No module R3-GC1 (4/4) 16 Words Slot No.6 No module No module ---- Slot No.7 R3-NE1 R3-NE1 ---- Slot No.8 R3-PS1 R3-PS1 ---- ■ OUTPUT DATA The gure below shows the allocation of the data sent from the network module to the master. ■ INPUT DATA The gure below shows the allocation of the data sent from the master to the network module. Use the DIP SW located at the side of the module to specify expanded cyclic setting. 16 words input and 16 words output make 1 cyclic. Max. 8 cyclic (128 words input, 128 words output) transmission is available. 1 cyclic is equivalent to 1 I/O module (analog input 16 points, analog output 16 points). Max. 8 I/O modules can be assigned to 8 slots. Note: Do not mount any modules in the slots which are occupied by virtual modules. If a real I/O module is mounted in the slot, an internal bus error occurs and the ERR LED turns on. Max. 16 real I/O modules and virtual modules are available. The interface module can not read the data for more than 16 modules. ■ WHEN R3-GC1 IS MOUNTED ON SLOT NO. 2 (4 CYCLIC) Real I/O modules are mounted on Slots No. 1 and 2, however, the network module (R3-NE1) recognizes that each of Slots No. 1 to 5 is occupied. That is, R3-NE1 recognizes R3-SV4 mounted on Slot No.1 as it is and recognizes R3-GC1 mounted on Slot No.2 as divided into four modules and occupying Slots No. 2 to 5. |
|
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |