  R3-GFL1S/CE Datasheet HTML 1Page - M-System Co.,Ltd. R3-GFL1S/CE Datasheet HTML 2Page - M-System Co.,Ltd. R3-GFL1S/CE Datasheet HTML 3Page - M-System Co.,Ltd. R3-GFL1S/CE Datasheet HTML 4Page - M-System Co.,Ltd. R3-GFL1S/CE Datasheet HTML 5Page - M-System Co.,Ltd. R3-GFL1S/CE Datasheet HTML 6Page - M-System Co.,Ltd.  
Zoom Inzoom in Zoom Outzoom out
 4 / 6 page
background image
MODEL: R3-GFL1
R3-GFL1 SPECIFICATIONS
ES-8461 Rev.13 Page 4/6
https://www.m-system.co.jp/
EXTERNAL VIEW
SW1
ON
8
7
6
5
4
3
2
1
Main
Configuration Jack
(unused)
ERR LED
LNK LED
HER LED
RUN/CFG Selector
I/O Configuration Jack
RUN LED
FRONT VIEW
SIDE VIEW
MAIN
ETHERNET
I/O
RX
TX
RUN Contact
Output
10BASE-T/100BASE-TX
RJ-45 Connector
PER LED
CFG LED
Module
Allocation
RX
TX
RX LED
TX LED
TRANSMISSION DATA DESCRIPTIONS
Use the DIP SW located at the side of the module to specify module allocation.
1 module is equivalent to 1 I/O module with 16 words analog input and 16 words analog output. Max. 8 modules (128 words
input, 128 words output) transmission is available. R3-GFL1 seems as if max. 8 I/O modules are mounted to 8 slots via FL-net.
The input of the module is processed as follows.
[FL-net Communication] --> [R3-GFL1 Module] --> [R3 Base] --> [R3 Communication Module]
The data set with output tab of R3-NFLBLD to input is transmitted to R3 communication module. Output is reversed. The data
set with transmitting area 1 and transmitting area 2 is transmitted to FL-net.
Note: Do not mount any modules in the slots which are occupied by virtual modules. If a real I/O module is mounted in the slot,
an internal bus error occurs. Max. 16 real I/O modules and virtual modules are available. The interface module can not read the
data for more than 16 modules.
■ WHEN R3-GFL1 IS MOUNTED ON SLOT NO. 2 (4 modules)
Real I/O modules are mounted on Slots No. 1 and 2, however, the network module (R3-NE1) recognizes that each of Slots No. 1
to 5 is occupied. That is, R3-NE1 recognizes R3-SV4 mounted on Slot No.1 as it is and recognizes R3-GFL1 mounted on Slot
No.2 as divided into four modules and occupying Slots No. 2 to 5.
SLOT
REAL MODULE
VERTUAL MODULE
NO. OF WORDS
Slot No.1
R3-SV4
R3-SV4
4 Words
Slot No.2
R3-GFL1
R3-GFL1 (1/4)
16 Words
Slot No.3
No module
R3-GFL1 (2/4)
16 Words
Slot No.4
No module
R3-GFL1 (3/4)
16 Words
Slot No.5
No module
R3-GFL1 (4/4)
16 Words
Slot No.6
No module
No module
----
Slot No.7
R3-NE1
R3-NE1
----
Slot No.8
R3-PS1
R3-PS1
----
1
2
3
4
5
6
7
8
R3-
SV4
R3-BS08
R3-
GFL1
R3-
NE1
R3-
PS1



Html Pages

1 2 3 4 5 6


データシート ダウンロード

Go To PDF Page


リンク URL



ALLDATASHEETはお客様のビジネスに役立ちますか?  [ DONATE ] 

Alldatasheetは   |   広告   |   お問い合わせ   |   プライバシーポリシー   |   データシートへのリンク    |   リンク交換   |   メーカーリスト
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com