| データシートサーチシステム |
|
R3-US4S/Q データシート(PDF) 1 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
R3-US4S/Q データシート(HTML) 1 Page - M-System Co.,Ltd. |
|
1 / 7 page ![]() MODEL: R3-US4 R3-US4 SPECIFICATIONS ES-8449 Rev.7 Page 1/7 http://www.m-system.co.jp/ Remote I/O R3 Series UNIVERSAL INPUT MODULE (4 points, isolated) 109 (4.29) 27.5 (1.08) 130 (5.12) mm (inch) MODEL: R3-US4[1][2] ORDERING INFORMATION • Code number: R3-US4[1][2] Specify a code from below for each of [1] and [2]. (e.g. R3-US4W/A/Q) • Specify the specification for option code /Q (e.g. /C01/SET) Factory default setting Input: DC voltage, ±12 V Temperature unit: °C Burnout: Upscale CJC: ON NO. OF CHANNELS 4: 4 [1] COMMUNICATION MODE S: Single W: Dual [2] OPTIONS (multiple selections) Temperature input accuracy blank: Standard /A: High accuracy Other Options blank: none /Q: Option other than the above (specify the specification) SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) /C01: Silicone coating /C02: Polyurethane coating /C03: Rubber coating EX-FACTORY SETTING /SET: Preset according to the Ordering Information Sheet (No. ESU-8449) RELATED PRODUCTS • PC configurator software (model: R3CON) Downloadable at M-System’s web site. A dedicated cable is required to connect the module to the PC. Please refer to the internet software download site or the users manual for the PC configurator for applicable cable types. GENERAL SPECIFICATIONS Connection Internal bus: Via the Installation Base (model: R3-BSx) Input: M3 separable screw terminal (torque 0.5 N·m) Internal power: Via the Installation Base (model: R3-BSx) Screw terminal: Nickel-plated steel Isolation: Input 1 to input 2 to input 3 to input 4 to internal bus or internal power Input range: Selectable with configuration software (model: R3CON) Temperature unit (Thermocouple or RTD input): Selectable with PC configuration software (model: R3CON) Burnout for T/C and RTD input: Upscale, downscale or no burnout selectable with PC configurator software Select “No burnout” to minimize the measuring errors caused by the sensor/wire resistance and the burnout sensing current. With RTD input, the signal may go transiently to the opposite direction from the burnout setting. Burnout is not detected at DC voltage or potentiometer input. The burnout sensing current is turned off. Cold junction compensation (CJC) for T/C input: CJC is selectable whether enabled or disabled by using the PC configurator software. The cold junction sensor is mounted to the terminal of each channel. A/D conversion mode: (Temp. input accuracy: standard) Low or middle conversion rate selectable with PC configurator software RUN indicator: Bi-color (red/green) LED; Red when the bus A operates normally; Green when the bus B operates normally; Amber when both buses operate normally. ERR indicator: Bi-color (red/ green) LED; Red with burnout; Green in normal operating conditions. INPUT SPECIFICATIONS ■ DC Voltage Input resistance: ≥ 600 kΩ |
同様の部品番号 - R3-US4S/Q |
|
同様の説明 - R3-US4S/Q |
|
|
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |