| データシートサーチシステム |
|
S8VK-R データシート(PDF) 9 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
S8VK-R データシート(HTML) 9 Page - Omron Electronics LLC |
|
9 / 12 page ![]() S8VK-R 9 Safety Precautions Warning Indications Meaning of Product Safety Symbols !CAUTION Risk of a mild burn on rare occasions. Do not touch the device unit while it is powered on or immediately after the power is turned off. The ignition may accidentally be caused. Tighten terminal screws to a specified torque 4.43 to 5.31 lb-in (0.5 to 0.6 N·m). Minor electric shock, fire, or Product failure may occasionally occur. Do not allow any pieces of metal or conductors or any clippings or cuttings resulting from installation work to enter the Product. Risk of product damage. Do not reverse the polarity of the device input terminals when wiring. Risk of internal component deterioration and damage. Do not connect an AC power supply. Minor electric shock, fire, or Product failure may occasionally occur. Do not disassemble, modify, or repair the Product or touch the interior of the Product. Wiring • Minor fire may possibly occur. Ensure that input and output terminals are wired correctly. • Increases in the temperature of internal parts resulting from heating of wiring materials may result in deterioration or damage to parts. Use wiring materials suitable to the current being used. The following wiring materials, torque and strip length are recommended to prevent heating and possible fires in wiring materials. • On rare occasions there is a risk of internal element deterioration and damage if use is continued in a short-circuit or over-current state. • Do not apply more than 75N force to the terminal block when tightening it. • Use within a range that does not exceed the output current rating. When a load short-circuit occurs, the short-circuit current of two power supply units flows. Use output wiring that can handle the short-circuit current of two units. If the wiring does not have sufficient current capacity, connect a fuse on the output side. Recommended fuse S8VK-R10: 15 A, S8VK-R20: 30 A Fast- acting type If the current rating of the output terminal is exceeded on the S8VK- R20, always use multiple terminals simultaneously. • Risk of damage to internal components. Do not use in a state that exceeds the rated current of the signal output. Installation Environment • Do not use the Redundancy Unit in locations subject to shocks or vibrations. In particular, install the Redundancy Unit as far away as possible from contactors or other devices that are a vibration source. • Install the Redundancy Unit well away from any sources of strong, high-frequency noise and surge. Ambient Operating and Storage Environments • Store the product with ambient temperature −40 to 85°C, and relative humidity 0 to 95%. • The internal parts may occasionally be deteriorated or broken. Do not use at a temperature that exceed the operating temperature range for the mounting type. • Use the product where the relative humidity is 0 to 95%. • Avoid places where the product is subjected to direct sunlight. • Avoid places where the product is subjected to penetration of liquid, foreign substance, or corrosive gas. • Avoid places subject to shock or vibration.A device such as a contact breaker may be a vibration source. Set the Redundancy Unit as far as possible from possible sources of shock or vibration. • If the Redundancy Unit is used in an area with excessive electronic noise or surge, be sure to separate the Redundancy Unit as far as possible from the noise sources. CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or in property damage. Precautions for Safe Use Supplementary comments on what to do or avoid doing, to use the product safely. Precautions for Correct Use Supplementary comments on what to do or avoid doing, to prevent failure to operate, malfunction or undesirable effect on product performance. Used to warn of the risk of minor injury caused by high temperatures. Used for general mandatory action precautions for which there is no specified symbol. Use to indicate prohibition when there is a risk of minor injury from electrical shock or other source if the product is disassembled. Precautions for Safe Use Terminal Model Recommend Wire Type AWG Solid wire Twisted wire Input S8VK-R10 AWG14 to 12 2.5 to 4 mm2 2.5 mm2 S8VK-R20 AWG12 to 10 4 to 6 mm2 4 mm2 Output S8VK-R10 AWG14 to 12 2.5 to 4 mm2 2.5 mm2 S8VK-R20 AWG12 to 10 4 to 6 mm2 4 mm2 Status contact S8VK-R @@ AWG16 1.5 mm2 --- All terminals wires to be stripped: 8 mm |
|
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |