| データシートサーチシステム |
|
BW250RAM データシート(PDF) 70 Page - Fuji Electric |
|
|
|||||||||||||||||||||||||||||
BW250RAM データシート(HTML) 70 Page - Fuji Electric |
|
70 / 93 page ![]() 06/70 Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice n Rating of shunt trip (F) n Rating of undervoltage trip (R) 7-13 13-21 8-20 AC DC Opearting time (ms) MCCB type BW32 BW50 BW63 BW100 BW125 BW160 BW250 BW400 BW630 BW800 V 100-120 200-240 380-450 24 24 48 100-120 120-130 200-240 277 380-440 440-480 500-550 24-48 100-240 277 380-550 24-48 100-220 VA 150 150 200 150 50 50 50 50 50 50 50 50 50 2 3 3 4 V 100-110 − − 24 24 48 100-110 − 200-220 − − − − Code FAC/DC24-48V FAC100-240V DC100-220V FAC277V FAC380-550V FAC100-120V/ DC100-110V FAC200-240V FAC380-450V FAC/DC24V FAC/DC24V FAC/DC48V FAC100-120V/ DC100-110V FAC120-130V FAC200-240V/ DC200-220V FAC277V FAC380-440V FAC440-480V FAC500-550V 2 3 − − Continuous W 150 − − 150 50 50 50 − 50 − − − − Continuous (With 1NO contact to prevent coil burn-out) Time rating of coil Note: The operating tripping voltage range for shunt trip devices is 70% to 110% of the rated operating voltage. 100 (50Hz)/ 100-110(60Hz) 200 (50Hz)/ 200-220 (60Hz) 400 (50Hz)/ 400-440 (60Hz) − − − − − 100-110 110-130 200-240 277 380-415 440-480 − − − 40 5 5 5 5 − − − − − − 2 2 3 3 3 − − − − − 24 100-110 24 48 100-110 125 − − − − − − BW32 *2 BW50 *2 BW63 *2 BW100 *2 BW125 *1 BW160 *1 BW250 *1 AC DC MCCB type Installation External Internal Internal Code RAC100(50Hz)/ 100-110V(60Hz) RAC200(50Hz)/ 200-220V(60Hz) RAC400(50Hz)/ 400-440V(60Hz) RDC24V RDC100-110V RDC24V RDC48V RDC100-110V RDC125V RAC100-110V RAC110V-130V RAC200-240V RAC277V RAC380-415V RAC440V-480V RAC/DC24V RAC/DC48V RAC/DC100-110V RAC120-130V/DC125V RAC200-240V/DC200-220V RAC277V RAC380-480V BW400 *2 BW630 *2 BW800 *2 V 24 48 100-110 120-130 200-240 277 380-480 24 48 100-110 125 200-220 − − VA V W Notes: • The operating voltages of undervoltage tripping devices are as follows: Tripping voltage: 35% to 70% of rated voltage, closing voltage: 85% to 110% of rated voltage. *1 Reset-allowed type: When the breaker handle is in the OFF or RESET state, tripping does not occur even if the R coil is not energized. Turning ON with the R coil not energized causes normal tripping. *2 Reset-prohibited type: When the R coil is not energized, reset operation cannot reset the tripped breaker to the OFF state. 2.8 3.4 4.4 − − − − − 5 5 5 5 5 5 2 2 3 3 3 3 4 Molded Case Circuit Breakers G-TWIN series Internal accessories |
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |