SEN012 データシート(HTML) 4 Page - Power Integrations, Inc.

  SEN012_V01 Datasheet HTML 1Page - Power Integrations, Inc. SEN012_V01 Datasheet HTML 2Page - Power Integrations, Inc. SEN012_V01 Datasheet HTML 3Page - Power Integrations, Inc. SEN012_V01 Datasheet HTML 4Page - Power Integrations, Inc. SEN012_V01 Datasheet HTML 5Page - Power Integrations, Inc. SEN012_V01 Datasheet HTML 6Page - Power Integrations, Inc. SEN012_V01 Datasheet HTML 7Page - Power Integrations, Inc. SEN012_V01 Datasheet HTML 8Page - Power Integrations, Inc.  
Zoom Inzoom in Zoom Outzoom out
 4 / 8 page
background image
Rev. C 05/15
4
SEN012-013
www.power.com
Application Example
SENZero in PFC Bus Voltage Feedback Network
Commercial PFC IC’s typically has a pin dedicated for sensing the
output voltage of the PFC Stage. The information on this pin is
typically used by the PFC IC for various major functions.
1. Output regulation – input to the non-inverting input of the error
amplifier.
2. OVP detection – input to the OVP comparator.
3. Open-loop protection – used to detect open-loop conditions.
The last 2 functions were used for protecting the bus from overvolt-
age condition.
Figure 11. PFC Bus Voltage Sense Network.
The SENZero objective is to eliminate the losses associated with the
sense resistors without affecting the functionality of the circuit. To
keep the operation of the PFC IC unaffected, SENZero and PFC on
and off event must follow the required timing sequence during power-
up, power-down, remote-on, and remote-off event.
PI-6203-102510
Error Amplifier
OLP
R1
R2
R3
RFB
CBULK
PFC VOUT
OVP
FB
PFC IC
SENZero
Switch
ON
ON
OFF
OFF
OFF
OFF
VCC
SENZero
PFC
PI-6205-102510
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
PS(ON)
SENZero
PFC
PI-6206-102510
Figure 12. Timing between PFC IC and SENZero during Power-Up and
Power-Down.
In case of shared VCC Connection, it must be ensure that SENZero
have a lower turn-on and turn-off threshold voltage compared to the
PFC IC.
Figure 13. Timing between PFC IC and SENZero with PS
(ON) Signal.
From off-state to on-state, SENZero must turn-on ahead of the PFC.
From on-state to off-state, PFC must shutdown ahead of the
SENZero. This is to ensure that whenever PFC is operating (switch-
ing), SENZero is invincible to the PFC. SENZero only disconnects the
sense resistors when PFC is in off-condition and thus eliminates its
associated losses during standby condition.



Html Pages

1 2 3 4 5 6 7 8


データシート ダウンロード

Go To PDF Page


リンク URL



ALLDATASHEETはお客様のビジネスに役立ちますか?  [ DONATE ] 

Alldatasheetは   |   広告   |   お問い合わせ   |   プライバシーポリシー   |   データシートへのリンク    |   リンク交換   |   メーカーリスト
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com