データシートサーチシステム
  Japanese  ▼
ALLDATASHEET.JP

X  

VIPERGAN50 データシート(PDF) 24 Page - STMicroelectronics

部品番号 VIPERGAN50
部品情報  Advanced quasi-resonant offline high voltage converter with E-mode GaN HEMT
PDF  37 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
メーカー  STMICROELECTRONICS [STMicroelectronics]
ホームページ  http://www.st.com
Logo STMICROELECTRONICS - STMicroelectronics

VIPERGAN50 データシート(HTML) 24 Page - STMicroelectronics

Back Button VIPERGAN50 Datasheet HTML 20Page - STMicroelectronics VIPERGAN50 Datasheet HTML 21Page - STMicroelectronics VIPERGAN50 Datasheet HTML 22Page - STMicroelectronics VIPERGAN50 Datasheet HTML 23Page - STMicroelectronics VIPERGAN50 Datasheet HTML 24Page - STMicroelectronics VIPERGAN50 Datasheet HTML 25Page - STMicroelectronics VIPERGAN50 Datasheet HTML 26Page - STMicroelectronics VIPERGAN50 Datasheet HTML 27Page - STMicroelectronics VIPERGAN50 Datasheet HTML 28Page - STMicroelectronics Next Button
Zoom Inzoom in Zoom Outzoom out
 24 / 37 page
background image
If VBR > VBR-DIS, the IC starts up and is allowed to switch for 30 msec. After that, if VBR > VBR-OUT (0.4 V, typ.),
it continues switching, otherwise it is disabled. From this latter case, if VBR exceeds VBR-IN (0.5 V, typ.) for more
than TBR_IN (250 usec, typ.), the IC is allowed to resume switching (brown-in); then, if VBR falls below VBR-OUT for
more than TBR_OUT (30 msec, typ.), the IC is disabled (brown-out).
The delay times are implemented through up/down counters, to reject temporary disturbances across the line.
TBR_OUT is also intended to avoid false protection triggerings due to the input capacitor voltage ripple and to
guarantee some hold-up in case of a missing cycle of the input line.
Input OVP, brown-in and brown-out conditions can be set connecting a voltage divider across the rectified input
mains, iOVP, BR and GND and selecting the resistor values according to the equations below.
Equation 10
(10)
ROVP=RHV∙ ViOVP_tℎ
VIN−OVP−VBR−IN
VIN−ON
Equation 11
(11)
RBR=RHV∙ VBR−IN
VIN−ON−VBR−IN
In the above formulas,
VIN_ONandVIN_OVParetheDCinputvoltageswhichtriggerbrown-inandinput
overvoltage protection respectively.
The resistor RHV is used to start up the converter and also as part of the voltage divider, once HV and iOVP
are connecter together. Its value is arbitrarily selected, with the recommendation to be few tens MΩ at least to
minimize the residual consumptions from the input mains.
It is worth noting that the thresholds VIN-ON and VIN-OFF (the input voltage values triggering brown-in and
brown-out respectively) cannot be set independently but are linked to each other. The DC bus voltage value that
turns off the device is thus calculated with the following equation.
Equation 12
(12)
VIN−OFF=VIN−ON∙VBR−OUT
VBR−IN
A 10 nF filter capacitor placed between BR pin and GND is necessary to avoid misbehavior of the brown-out logic
when a high voltage start-up unit is activated.
The brown-in/out function can be disabled connecting the BR to GND.
VIPERGAN50
Brown-In and Brown-Out protection
DS13888 - Rev 2
page 24/37



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37


データシート ダウンロード

Go To PDF Page


リンク URL



ALLDATASHEETはお客様のビジネスに役立ちますか?  [ DONATE ] 

Alldatasheetは   |   広告   |   お問い合わせ   |   プライバシーポリシー   |   データシートへのリンク    |   リンク交換   |   メーカーリスト
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com