| データシートサーチシステム |
|
E5CN-R2TU データシート(PDF) 10 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
E5CN-R2TU データシート(HTML) 10 Page - Omron Electronics LLC |
|
10 / 24 page ![]() 10 Digital Temperature Controllers E5CN/E5CN-U External Connections • A voltage output (control output) is not electrically insulated from the internal circuits. When using a grounding thermocouple, do not connect any of the control output terminals to ground. If the control output terminals are connected to ground, errors will occur in the measured temperature values as a result of leakage current. • Standard insulation is applied between any of the following: power supply terminals, input terminals, output terminals, and communications terminals (for models with communications). If reinforced insulation is required, provide additional insulation, such as spacial distance or material insulation, as defined by IEC 60664 suitable for the maximum operating voltage. Relay Output Voltage Output Terminals 11 to 15 do not exist on models without an Option Unit (heater burnout detection, control output 2, event inputs, or communications). Terminal applications depend on the model of the Option Unit. − + + − + Alarm Outputs Control output 1 Alarm 1/ Heater burnout alarm/ Input error output (See note.) Alarm 2 Analog input Current Output Infrared temperature sensor Communications/ Heater burnout/ SSR failure detection (2-CT input) Platinum resistance thermometer Communications/ voltage output specification + − Do not connect. Voltage output/ Heater burnout/ SSR failure detection + − Control output 2 Do not connect. Event input 1 Event input 2 Event input/ Heater burnout / SSR failure detection Heater burnout/ SSR failure detection input Heater burnout/ SSR failure detection input Voltage output 12 VDC, 21 mA Heater burnout/ SSR failure detection input The input power supply depends on the power supply specification of the Controller and is either 100 to 240 VAC or 24 VAC/DC (no polarity). Note: Output when an input error output is enabled in the Advance Function Setting Level. If an input error output is enabled, the a1-1 operation indication on the front panel will not light and s.err will be displayed on the No. 1 display. 6 7 8 9 10 11 12 13 14 15 1 3 2 4 5 11 12 13 14 15 B Pt TC A B B A V mA 6 7 8 1 2 1 2 1 2 RS-485 CT1 CT2 11 12 13 14 15 B A RS-485 11 12 13 14 15 11 12 13 14 15 CT1 CT1 − + 4 to 20 mA DC/ 0 to 20 mA DC − + 12 VDC 21 mA Input power supply Control output 2 Voltage output 12 VDC, 21 mA E5CN 7 8 9 10 11 1 2 3 4 6 Voltage Output Pt TC Alarm 1/ Input error output (See note.) Control output 1 Input power supply Do not connect. 7 8 9 Alarm 1/ Input error output Alarm 2/ Control output 2 Analog input A B B + + + − − − DC12V 21mA 5 4 Relay Output One Alarm Output Two Alarm Outputs 5 Infrared temperature sensor Platinum resistance thermometer The input power supply depends on the power supply specification of the Controller and is either 100 to 240 VAC or 24 VAC/DC (no polarity). Order the P2CF-11 or P3GA-11 Socket separately. (See page 14.) Note: Output when an input error output is enabled in the Advance Function Setting Level. If an input error output is enabled, the al-1 operation indication on the front panel will not light and s.err will be displayed on the No. 1 display. 0 to 50 mV input only E5CN-U |
|
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |