Back Button LM10502TLX/NOPB Datasheet HTML 17Page - Texas Instruments LM10502TLX/NOPB Datasheet HTML 18Page - Texas Instruments LM10502TLX/NOPB Datasheet HTML 19Page - Texas Instruments LM10502TLX/NOPB Datasheet HTML 20Page - Texas Instruments LM10502TLX/NOPB Datasheet HTML 21Page - Texas Instruments LM10502TLX/NOPB Datasheet HTML 22Page - Texas Instruments LM10502TLX/NOPB Datasheet HTML 23Page - Texas Instruments LM10502TLX/NOPB Datasheet HTML 24Page - Texas Instruments LM10502TLX/NOPB Datasheet HTML 25Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 21 / 34 page
background image
2.9V
BG/BIAS
UVLO internal status
LDO Vout
Buck1 Vout
2 ms
2 ms
Buck2 Vout
VIN
IRQ (LDO
driving VIN_IO)
2ms
0V
STARTUP
STARTUP
UVLO
UVLO
OVLO
15 ms
15 ms
2ms
OVLO internal status
3.0V
3.0V
1.8V
1.2V
1.8V
1.2V
~3.2V
~2.25V
2.6V
VCOMP_ FALL
5.65V
5.75V
LM10502
www.ti.com
SNVS884B – AUGUST 2012 – REVISED MAY 2013
Device Operating Modes
STARTUP SEQUENCE
The startup mode of the LM10502 will depend on the input voltage. Once VIN reaches the UVLO threshold, there
is a 15 msec delay before the LM10502 determines how to set up the buck regulators. If VIN is greater than 3.6V,
the bucks will start up as the standard regulators. The 2 buck regulators are staggered during startup to avoid
large inrush currents. There is a fixed delay of 2 msec between the startup of each regulator.
The Startup Sequence will be:
1. 15 msec (±30%) delay after VIN above UVLO
2. LDO
→ 3V
3. 2 msec delay
4. Buck 1
→ 1.8V
5. 2 msec delay
6. Buck 2
→ 1.2V
Figure 23. Operating Modes
POWER-ON DEFAULT AND DEVICE ENABLE
The device is always enabled and the LDO is always on, unless outside of operating voltage range. There is no
LM10502 Enable Pin. Once VIN reaches a minimum required input Voltage the power-up sequence will be
started automatically and the startup sequence will be initiated. Once the device is started, the output voltage of
the Bucks can be individually disabled by accessing their corresponding BKEN register bits (BUCK CONTROL).
RESET: PIN FUNCTION
The RESET pin is internally pulled high. If the reset pin is pulled low, the device will perform a complete reset of
all the registers to their default states. This means that all of the voltage settings on the regulators will go back to
their default states.
Copyright © 2012–2013, Texas Instruments Incorporated
Submit Documentation Feedback
21
Product Folder Links: LM10502



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34


データシート ダウンロード

Go To PDF Page


リンク URL



ALLDATASHEETはお客様のビジネスに役立ちますか?  [ DONATE ] 

Alldatasheetは   |   広告   |   お問い合わせ   |   プライバシーポリシー   |   データシートへのリンク    |   リンク交換   |   メーカーリスト
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com