16 / 20 page ![]() Electrical specification L9911 16/20 DocID10990 Rev 13 Note: The diagnostic result is disabled during the Soft-start delay time t_ST 0...3 and the soft-start / soft attack timing t_SL 0...3 Figure 14. DF monitor electrical configuration Figure 15. Short circuit drivers' protection Field driver, DFMon driver and Relay driver are protected in switching mode (not linear), with a retry time less than 25 ms. Lamp driver is protected in linear mode, with a retry time of 1 s. Table 10. Fault detection Root cause Signal Effect Test detect Alternator belt breaking P Alternator disexcitation VP<VPHH1 & VB+<Vreg Brushes open P Alternator disexcitation VP<VPHH1 & VB+<Vreg Field driver open P Alternator disexcitation VP<VPHH1 & VB+<Vreg Field interruption P Alternator disexcitation VP<VPHH1 & VB+<Vreg Field short circuit to the battery F+ Overvoltage VF+>VS1 & VB+ > Vov-d Field short circuit to the ground P Alternator disexcitation VP<VPHH1 & VB+<Vreg Battery discharge B+ Undervoltage VB+<Vuv |
|
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|