| データシートサーチシステム |
|
SPSB100 データシート(PDF) 11 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
SPSB100 データシート(HTML) 11 Page - STMicroelectronics |
|
11 / 213 page ![]() • BUCK2 (5.0 V): charged with 1 A (DC activation) at 2.4 MHz • BUCK3 (0.98 V): charged with 2 A (DC activation) at 2.4 MHz Note: 1. BUCK3 load current is already considered in the power dissipation calculation, so 1 A is referred to BUCK1 external loads current. 2. Selecting the switching frequency at 2.4 MHz for BUCK1 and BUCK2 will lower the regulators efficiency and this extra power to be dissipated can generate a faster thermal shut-down. In case the application requires a high DC current load, it is strongly suggested using the switching frequency at 400 kHz for BUCK1 and BUCK2. The following curves show the relationship between max power dissipation vs ambient temperature: Figure 4. Max power dissipation vs ambient temperature for case "A" and case "B" 0.000 0.500 1.000 1.500 2.000 2.500 3.000 3.500 4.000 4.500 5.000 -50 -25 0 25 50 75 100 125 150 175 200 Tamb. [°C] Pwr_A [W] Pwr_B [W] SPSB100 Maximum ratings DS14640 - Rev 2 page 11/213 |
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |