  S-8232 Datasheet HTML 1Page - Seiko Instruments Inc S-8232 Datasheet HTML 2Page - Seiko Instruments Inc S-8232 Datasheet HTML 3Page - Seiko Instruments Inc S-8232 Datasheet HTML 4Page - Seiko Instruments Inc S-8232 Datasheet HTML 5Page - Seiko Instruments Inc S-8232 Datasheet HTML 6Page - Seiko Instruments Inc S-8232 Datasheet HTML 7Page - Seiko Instruments Inc S-8232 Datasheet HTML 8Page - Seiko Instruments Inc S-8232 Datasheet HTML 9Page - Seiko Instruments Inc Next Button
Zoom Inzoom in Zoom Outzoom out
 4 / 27 page
background image
BATTERY PROTECTION IC FOR 2-SERIAL-CELL PACK
S-8232 Series
Rev.5.4_00
Seiko Instruments Inc.
4
Table 1 (2 / 2)
Product name / Item
Overcharge
detection
voltage 1, 2
VCU
Overcharge
release voltage 1, 2
VCD
Overdischarge
detection
voltage 1, 2
VDD
Overdischarge
release
voltage1, 2
VDU
Overcurrent
detection
voltage 1
VIOV1
Overcharge
detection
delay time
tCU
(C3
= 0.22 µF)
0 V battery
charging
function
S-8232NAFT-T2-G 4.325 V
± 25 mV 4.325 V ± 25 mV
*1 *3
2.40 V
± 80 mV 3.00 V ± 100 mV 0.15 V ± 20 mV
1.0 s
Unavailable
S-8232NBFT-T2-G
4.35 V
± 25 mV
4.25 V
± 50 mV
3.00 V
± 80 mV 3.70 V ± 100 mV 0.30 V ± 20 mV
1.0 s
Unavailable
S-8232NCFT-T2-G 4.275 V
± 25 mV
4.05 V
± 50 mV
2.20 V
± 80 mV 3.00 V ± 100 mV 0.20 V ± 20 mV
1.0 s
Unavailable
S-8232NDFT-T2-G
4.35 V
± 25 mV
4.15 V
± 50 mV
2.30 V
± 80 mV 2.30 V ± 80 mV
0.15 V
± 20 mV
1.0 s
Available
S-8232NEFT-T2-G
4.35 V
± 25 mV
4.15 V
± 50 mV
2.30 V
± 80 mV 3.00 V ± 100 mV 0.23 V ± 20 mV
1.0 s
Available
S-8232NFFT-T2-G
4.325 V
± 25 mV
4.1 V
± 50 mV
*3
2.30 V
± 80 mV 2.90 V ± 100 mV 0.21 V ± 20 mV
1.0 s
Unavailable
S-8232NGFT-T2-G
4.35 V
± 25 mV
4.15 V
± 50 mV
2.60 V
± 80 mV 3.00 V ± 100 mV 0.30 V ± 20 mV
1.0 s
Available
S-8232NHFT-T2-G
4.28 V
± 25 mV
4.05 V
± 50 mV
2.30 V
± 80 mV 2.90 V ± 100 mV 0.11 V ± 20 mV
1.0 s
Unavailable
S-8232NIFT-T2-G
4.25 V
± 25 mV
4.05 V
± 50 mV
*3
2.50 V
± 80 mV 3.00 V ± 100 mV 0.15 V ± 20 mV
1.0 s
Unavailable
S-8232NJFT-T2-G
4.28 V
± 25 mV
4.05 V
± 50 mV
2.30 V
± 80 mV 2.90 V ± 100 mV 0.11 V ± 20 mV
1.0 s
Available
S-8232NKFT-T2-G
4.35 V
± 25 mV
4.15 V
± 50 mV
2.30 V
± 80 mV 2.30 V ± 80 mV
0.12 V
± 20 mV
1.0 s
Available
S-8232NLFT-T2-G
4.30 V
± 25 mV
4.05 V
± 50 mV
2.30 V
± 80 mV 3.00 V ± 100 mV 0.23 V ± 20 mV
1.0 s
Available
S-8232NMFT-T2-G 4.28 V
± 25 mV
4.05 V
± 50 mV
2.30 V
± 80 mV 2.90 V ± 100 mV 0.08 V ± 20 mV
1.0 s
Available
S-8232NNFT-T2-G 4.28 V
± 25 mV
4.08 V
± 50 mV
*3
2.20 V
± 80 mV 2.40 V ± 100 mV 0.13 V ± 20 mV
1.0 s
Unavailable
S-8232NOFT-T2-G 4.295 V
± 25 mV 4.045 V ± 50 mV
*3
2.20 V
± 80 mV 2.40 V ± 100 mV 0.13 V ± 20 mV
1.0 s
Unavailable
S-8232NPFT-T2-G 4.25 V
± 25 mV
4.05 V
± 50 mV
2.30 V
± 80 mV 3.00 V ± 100 mV 0.30 V ± 20 mV
1.0 s
Unavailable
S-8232NQFT-T2-G
4.25 V
± 25 mV
4.05 V
± 50 mV
2.60 V
± 80 mV 3.00 V ± 100 mV 0.30 V ± 20 mV
1.0 s
Unavailable
S-8232NRFT-T2-G 4.15 V
± 25 mV
3.95 V
± 50 mV
2.60 V
± 80 mV 3.00 V ± 100 mV 0.30 V ± 20 mV
1.0 s
Unavailable
S-8232NSFT-T2-G 4.15 V
± 25 mV
3.95 V
± 50 mV
2.30 V
± 80 mV 3.00 V ± 100 mV 0.30 V ± 20 mV
1.0 s
Unavailable
S-8232NTFT-T2-G 4.225 V
± 25 mV
4.15 V
± 50 mV
2.00 V
± 80 mV 2.00 V ± 100 mV 0.09 V ± 20 mV
1.0 s
Unavailable
S-8232NUFT-T2-G 3.85 V
± 25 mV
3.75 V
± 50 mV
2.23 V
± 80 mV 2.23 V ± 80 mV
0.15 V
± 20 mV
1.0 s
Available
S-8232NWFT-T2-G 4.210 V
± 25 mV 4.125 V ± 50 mV 2.00 V ± 80 mV 2.00 V ± 80 mV 0.09 V ± 20 mV
1.0 s
Unavailable
*1.
No overcharge detection / release hysteresis
*2.
The magnification of final overcharge is 1.11; the others are 1.25.
*3.
No final overcharging function
*4.
Refer to the *2 in the “ Operation”.
Remark 1.
Please contact our sales office for the products with detection voltage value other than those
specified above.
2.
The overdischarge detection voltage can be selected within the range from 1.7 to 3.0 V. When the
overdischarge detection voltage is higher than 2.6 V, the overcharge detection voltage and the
overcharge release voltage are limited as “Table 2”.
Table 2
Overdischarge
detection voltage 1, 2
VDD
Overcharge
detection voltage 1, 2
VCU
Voltage difference between overcharge detection
voltage and overcharge release voltage
VCU
− VCD
1.70 to 2.60 V
3.85 to 4.60 V
0 to 0.30 V
1.70 to 2.80 V
3.85 to 4.60 V
0 to 0.20 V
1.70 to 3.00 V
3.85 to 4.50 V
0 to 0.10 V



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27


データシート ダウンロード

Go To PDF Page


リンク URL



ALLDATASHEETはお客様のビジネスに役立ちますか?  [ DONATE ] 

Alldatasheetは   |   広告   |   お問い合わせ   |   プライバシーポリシー   |   データシートへのリンク    |   リンク交換   |   メーカーリスト
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com