| データシートサーチシステム |
|
C196 データシート(PDF) 2 Page - Time Electronics Ltd. |
|
|
|||||||||||||||||||||||||||||
C196 データシート(HTML) 2 Page - Time Electronics Ltd. |
|
2 / 2 page ![]() Time Electronics 7040 Digital Pressure Calibrator Time Electronics Ltd, Unit 5, TON Business Park, 2-8 Morley Road, Tonbridge, Kent, TN9 1RA, United Kingdom T: +44 (0) 1732 355993 | F: +44 (0) 1732 350198 | mail@timeelectronics.co.uk | www.timeelectronics.com v2b 06/22 Due to continuous development Time Electronics reserves the right to change specifications without prior notice. Technical Specifications Pressure Range (bar) 0.2 2 5 10 20 Accuracy (% FS) 0.1 0.04 (0.025*) 0.04 (0.025*) 0.04 (0.025*) 0.04 (0.025*) Resolution (bar) 0.01 mbar .0001 0.001 0.001 0.001 * High accuracy available, specify range code + HA on order Vacuum........................................................................ Available on 2 bar range. Measures vacuum to - 1 bar. Filter............................................................................. Off (4 readings/sec), average of 4 readings, or average of 16 readings. Temperature stability.................................................. Less than 0.005 % per °C. Sensor ......................................................................... Piezoresistive. Pressure connection..................................................1/8 ” BSP female in a stainless steel manifold. Over-pressure............................................................. 3 x full scale or, 35 bar. Wetted parts................................................................ Stainless steel and silicon (contaminated media version - stainless steel only). Units............................................................................. Bar, PSI, KPa, inWg, cmWg, inHg, mmHg, Kg/cm2, Atm. Loop Current Calibration Ranges ................................................................... ± 200 mA, and ‘% of 4 - 20 mA’. Accuracy ................................................................. 0.05 % of reading ± 2 digit, (0.1 % for ‘% of 4 - 20 mA’ range). Resolution .............................................................. 10 μA (200 mA range), 0.1 % (% of 4 - 20 mA range). Loop resistance ...................................................... Less than 2 Ω. Protection ............................................................... 250 mA automatic reset Poly-Fuse. Sockets ................................................................... 4 mm industry standard. Display Pressure display..................................................... In one of 9 user selectable units. Loop current display .............................................. In mA or % of 4 - 20 mA. Leak rate display .................................................... In pressure units per sec, or per minute, as selected in user set-up Max/Min logging display. General Specifications Power ..................................................................... PP3 battery, life 50 hours continuous use. Front panel ............................................................. Polycarbonate membrane keypad. Interfaces ................................................................ RS-232 for readback and re-calibration (software not supplied). Operating temperature ........................................... 0 to 50 °C. Storage temperature .............................................. -10 to 60 °C. Case ....................................................................... Structural resin which is weather-proof to IP66 standard. Dimensions / Weight .............................................. H 157 x W 90 x D 33 mm, weight 0.29 kg. Supplied with .......................................................... Carry case, pneumatic fittings kit and hose, test lead, serial link cable. Optional Extras ....................................................... Pneumatic hand pumps, EasyCal calibration software, and calibration certificates. Ordering Information 7040.......................................................................... Digital Pressure Calibrator 7040/71xx/C or A (pressure range code a shown below). Range (bar) 0.2 2 5 10 20 Option Code 7100 7101 (HA) 7102 (HA) 7103 (HA) 7104 (HA) For contaminated media version add /C. For absolute pressure sensor add /A 7090 ............................................................................. Pneumatic Hand Pump (vacuum to 40 bar). See separate datasheet for options. 7006 ....................................................................... Loop-Mate 1: Loop Current Simulator. ECFLA.......................................................................... EasyCal Calibration Software (see separate datasheet for further information). C185............................................................................. Traceable calibration certificate (Factory). C196............................................................................. Accredited calibration certificate (ISO 17025). |
|
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |