| データシートサーチシステム |
|
AHT20 データシート(PDF) 13 Page - ASAIR All Rights Reserved. |
|
|
|||||||||||||||||||||||||||||
AHT20 データシート(HTML) 13 Page - ASAIR All Rights Reserved. |
|
13 / 16 page ![]() www.aosong.com Version:V1.0 —— May 2021 AHT20 Data Sheet 13 / 16 Trigger measurement data Read temperature and humidity data Note: The sensor needs time to collect. After the host sends a measurement command (0xAC), delay more than 80 milliseconds before reading the converted data and judging whether the returned status bit is normal. If the status bit [Bit7] is 0, it means that the data can be read normally. When it is 1, the sensor is busy, and the host needs to wait for the data processing to complete. 8 Signal Conversion 8.1 Relative Humidity Conversion The relative humidity RH can be calculated according to the relative humidity signal SRH output by SDA through the following formula (the result is expressed in %RH): % 100 * ) 2 S ( [%] RH 20 RH 8.2 Temperature Conversion The temperature T can be calculated by substituting the temperature output signal ST into the following formula: (The result is expressed in temperature ℃): 50 - 200 * 2 S ] [ T 20 T ) ( ℃ |
|
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |