| データシートサーチシステム |
|
UFS330A41/Z データシート(PDF) 1 Page - TOKYO KEISO CO.,LTD. |
|
|
|||||||||||||||||||||||||||||
UFS330A41/Z データシート(HTML) 1 Page - TOKYO KEISO CO.,LTD. |
|
1 / 6 page ![]() OUTLINE Our clamp-on type Ultrasonic Flowmeter UL350 has enabled ap- plications to piping in various kinds by enhancing the permeation property of ultrasonic wave. “Time-Flight” type flowmeter is capable of measuring a flow rate of metallic and plastic piping ranging from 25 to 1000 mm in nominal diameter. A detector (an ultrasonic sensor) is mounted outside an existing piping by clamping method, so that it does not get into contact with the measuring fluid at all, and there are no concerns about the mixture of solid material and metallic ion into the fluid, the corrosion of sensor by chemical, and the pressure loss by installing the flow- meter. FEATURES ❏ The sensor of ultrasonic flowmeter UL350 is clamped on just outside of an existing pipe without any piping modification and time consuming installation work. ❏ By adopting a DSP and an AD converters, the flow measurement has been speeded up, and the resistance to bubbles has been improved. ❏ Because of the noncontact measurement method, the formation of bubbles and the mixture of metallic ion have been completely prevented. ❏ Installing the flowmeter does not cause the pressure loss because of no obstacles in the measuring pipe. ❏ The ultrasonic flowmeter is not affected by the pressure or con- ductivity of fluids. ❏ Excellent in long-term stability because of no moving part. ❏ Providing the following functions: Forward/backward flow rate display, totalizing display, analog output, pulse output, status output. ❏ Capable of controlling the flow rate with digital data by RS-485 serial output. (Forward/backward flow rate output, totalizing output, and status output by the Modbus protocol) ❏ A multi-drop connecting method has greatly reduced the signal wire. ❏ Complied with RoHS. Applying for EMC standards. MEASUREMENT PRINCIPLE CLAMP-ON TYPE UL350 ULTRASONIC FLOWMETER As shown in Fig. 1, an ultrasonic is transferred from A to B and B to A in turn with a angle of ψ. The required durations of transfer of two directions are different when measuring medium is moving from up stream to down stream. The durations of transfer are expressed by the following formula. tAB = L / (Co + Vm COS ψ) tBA = L / (Co – Vm COS ψ) Where L :Distance between A and B Vm :Average velocity of medium Co :Sonic speed in stable medium tAB, tBA :Duration of transfer of Ultra Sonic from A to B and B to A By measuring the difference of the transfer duration, the average velocity of medium can be calculated. The calculation is done by the following formula: 2Vm cos ψ = L / tAB – L/tBA ψ = L (tBA – tAB) / (tBA × tAB) Vm = L (tBA – tAB) / (2cos ψ × tBA × tAB) The distance between A and B (L) and the angle ( ψ) are known, and the average velocity is mathematically calculated. B Vm VBA VBA L A A B Ψ Fig. 1 TG-F2334-E00 1st edition Dec 2022 K |
同様の部品番号 - UFS330A41/Z |
|
同様の説明 - UFS330A41/Z |
|
|
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |