| データシートサーチシステム |
|
AV3402649 データシート(PDF) 16 Page - Panasonic Semiconductor |
|
|
|||||||||||||||||||||||||||||
AV3402649 データシート(HTML) 16 Page - Panasonic Semiconductor |
|
16 / 17 page ![]() Technical Terminology & Cautions for Use –5– AECTB36E 201510-T ■ Usage, storage, and transport conditions During usage, storage, or transportation, avoid locations subject to direct sunlight and maintain normal temperature, humidity, and pressure conditions. The allowable specifications for environments suitable for usage, storage, and transportation are given below. 1) Temperature: The allowable temperature range differs for each switch, so refer to the switch’s individual specifications. In addition, when transporting or storing switches while they are tube packaged, there are cases when the temperature may differ from the allowable range. In this situation, be sure to consult the individual specifications. 2) Humidity: 5 to 85% R.H. 3) Pressure: 86 to 106 kPa The humidity range varies with the temperature. Use within the range indicated in the graph below. (The allowable temperature depends on the switch.) • Condensation will occur inside the switch if there is a sudden change in ambient temperature when used in an atmosphere of high temperature and high humidity. This is particularly likely to happen when being transported by ship, so please be careful of the atmosphere when shipping. Condensation is the phenomenon whereby steam condenses to cause water droplets that adhere to the switch when an atmosphere of high temperature and humidity rapidly changes from a high to low temperature or when the switch is quickly moved from a low humidity location to one of high temperature and humidity. Please be careful because condensation can cause adverse conditions such as deterioration of insulation, coil cutoff, and rust. • Condensation or other moisture may freeze on the switch when the temperatures is lower than 0°C 32°F. This causes problems such as sticking of movable parts or operational time lags. • The plastic becomes brittle if the switch is exposed to a low temperature, low humidity environment for long periods of time. • Storage for extended periods of time (including transportation periods) at high temperatures or high humidity levels or in atmospheres with organic gases or sulfide gases may cause a sulfide film or oxide film to form on the surfaces of the contacts and/or it may interfere with the functions. Check out the atmosphere in which the units are to be stored and transported. • In terms of the packing format used, make every effort to keep the effects of moisture, organic gases and sulfide gases to the absolute minimum. ■ We reserve the right to modify without notice the materials, internal components, and other parts to improve product quality. ■ Handling precautions When handling the switches, be careful not to drop them on the floor since this may damage them. * Select contact sulfurization (clipping) prevention products (FS and Au-clad double layer contacts) for use with extremely small loads or an environment-resistant Turquoise switch. ■ Others 1) Failure modes of switches include short-circuiting, open- circuiting and temperature rises. If this switch is to be used in equipment where safety is a prime consideration, examine the possible effects of these failures on the equipment concerned, and ensure safety by providing protection circuits or protection devices. In terms of the systems involved, make provision for redundancy in the design and take steps to achieve safety design. 2) The ambient operating temperature (and humidity) range quoted is the range in which the switch can be operated on a continuous basis: it does not mean that using the switch within the rating guarantees the durability performance and environment withstanding performance of the switch. For details on the performance guarantee, check the specifications of each product concerned. Tolerance range (Avoid condensation when used at temperatures higher than 0 °C 32°F) (Avoid freezing when used at temperatures lower than 0 °C 32°F) 85 5 –40 –40 0 +32 +85 +185 Temperature, °C °F Humidity, %R.H. |
|
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |