32 / 204 page ![]() 30 www.lemo.com Mechanical and Climatical Technical Characteristics These plug, socket and coupler models allow the device on which they are fitted to reach a protection index of IP68 as per IEC 60529. They are fully compatible with plugs of the same series and are widely used for portable radios, military, laboratory equipment, aviation, etc. These models are identified by a letter «P» at the end of the reference. Most of these models are also available in a vacuumtight version. Such models are identified by an additional letter «V» at the end of the part number (certificate on request). Epoxy resin is used to seal these models. Watertight or vacuumtight models Characteristics Value Standard > 5000 cycles IEC 60512-5 test 9a up to 95% at 60° C - 20° C/+ 100° C - 20° C/+ 80° C > 1000h IEC 60512-6 test 11f 20/80/21 IEC 60068-1 < 10-7 mbar.l.s-1 IEC 60512-7 test 14b Endurance1) Humidity Temperature range Salt spray corrosion test4) Climatical category Leakage rate (He)2) Characteristics Value Standard 60 bar IEC 60512-7 test 14d 60 bar IEC 60512-7 test 14d 60 bar IEC 60512-7 test 14d 40 bar IEC 60512-7 test 14d 30 bar IEC 60512-7 test 14d 15 bar IEC 60512-7 test 14d 5 bar IEC 60512-7 test 14d Maximum operating pressure3) Dimensions (mm) A B e E L M S1 S3 YHG Fixed plug, nut fixing, non-latching, key (G) or keys (A…M) YHG 0B YHG 1B YHG 2B YHG 3B Reference Model Series 13 12.4 M9x0.6 2.4 24.1 14.2 8.2 11 16 15.8 M12x1.0 3.9 28.0 16.2 10.5 14 19 19.2 M15x1.0 5.5 33.1 17.8 13.5 17 22 25.0 M18x1.0 5.1 38.2 22.2 16.5 22 S 3 M L maxi S 1 E maxi Note: this model does not include an O-ring behind the flange, it ensures only IP61 protection index. Consequently, it is not vacuumtight. Water- tightness (when mated) is only ensured with HHG and HCG sockets. P9 Panel cut-out (page 157) 00 0B 1B 2B 3B 4B 5B 00 to 1B 2B to 5B Note: 1) see page 189, contact resistance after mating cycles. See page 185, mechanical endurance latching force. 2) only for vacuumtight models. Residual traces of grease used during (He) leak testing are on the o-ring. Please contact us for further details. 3) this value corresponds to the maximum allowed pressure difference for the assembled socket. 4) for chrome plated product («C» material code). ® ® |
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |