| データシートサーチシステム |
|
L6713ATR データシート(PDF) 57 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L6713ATR データシート(HTML) 57 Page - STMicroelectronics |
|
57 / 64 page ![]() L6713A Tolerance band (TOB) definition 57/64 23.4 Temperature measurement error (VTC) Error in the measured temperature (for thermal compensation) impacts on the output regulated voltage since the correction form the compensation circuit is not what required to keep the output voltage flat. The measurement error ( ε Temp) must be multiplied by the copper temp coefficient (α) and compared with the sensing resistance (RSENSE): this percentage affects the AVP voltage as follow: V TC αε Temp ⋅ R SENSE ------------------------ V AVP ⋅ = |
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|