| データシートサーチシステム |
|
M32C/8B データシート(PDF) 202 Page - Renesas Technology Corp |
|
|
|||||||||||||||||||||||||||||
M32C/8B データシート(HTML) 202 Page - Renesas Technology Corp |
|
202 / 406 page ![]() Under development M32C/8B Group 16. Three-Phase Motor Control Timer Function Preliminary specification Specifications in this manual are tentative and subject to change. REJ09B0450-0050 Rev.0.50 Oct 31, 2008 Page 185 of 385 Figure 16.7 TB2SC Register, ICTB2 Register Bit Name b7 0 0 0 0 0 0 0 b6 b5 b4 b1 b2 b3 Symbol TB2SC Address 035Eh After Reset 00h b0 Function Bit Symbol RW Timer B2 Special Mode Register RW RW PWCON Timer B2 reload timing switch bit 0: Timer B2 underflow 1: Timer B2 underflow at the rising edge of the timer A1 reload control signal (every odd-numbered timer B2 underflow) − (b7-b1) Reserved bits Set to 0 Timer B2 Interrupt Generation Frequency Set Counter(1, 2) Symbol ICTB2 Address 030Dh RW After Reset Undefined NOTES: 1. Read-modify-write instructions cannot be used to set the ICTB2 register. Refer to Usage Notes for details. 2. If the INV01 bit in the INVC0 register is set to 1, set the ICTB2 register while the TB2S bit is set to 0 (count stops). If the INV01 bit is set to 0, do not set the ICTB2 register when timer B2 underflows, regardless of the TB2S bit setting. − b7 b0 Function Unimplemented. Write 0. Read as undefined value. Setting Range b6 b5 b4 b3 WO 1 to 15 - When the INV01 bit in the INVC0 register is set to 0 (the ICTB2 counter increments every timer B2 underflows) and a setting value is n, the timer B2 interrupt request is generated every n-th timer B2 underflow. - When bits INV01 and INV00 are set to 10b (the ICTB2 counter increments when the timer B2 underflow at the rising edge of the timer A1 reload control signal) and a setting value is n, the first timer B2 interrupt request is generated at the (2n-1)th timer B2 underflow. From the 2nd time on, the request is generated every 2n-th timer B2 underflow. - When bits INV01 and INV00 are set to 11b (the ICTB2 counter increments when the timer B2 underflow occurs at the falling edge of the timer A1 reload control signal) and a setting value is n; • When n > 1, the first timer B2 interrupt request is generated at the (2n-2)th timer B2 underflow. From the 2nd time on, the request is generated every 2n-th timer B2 underflow. • When n = 1, the timer B2 interrupt request is generated every 2n-th timer B2 underflow. |
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |