208 / 406 page ![]() Under development M32C/8B Group 16. Three-Phase Motor Control Timer Function Preliminary specification Specifications in this manual are tentative and subject to change. REJ09B0450-0050 Rev.0.50 Oct 31, 2008 Page 191 of 385 Figure 16.12 Triangular Wave Modulation Operation (Three-Phase Mode 1)(INV01 and INV00 = 10b) Dead time DUB0 = 0 a 1 b 1 Triangular Waveform as a Carrier Wave (Three-phase mode 1: INV01 and INV00 = 10b) Carrier wave TB2S bit in the TABSR register Signal wave Timer B2 Timer A4 start trigger signal(1) TA4 register Reload register(1) b 2 a 2 b 3 a 3 b 4 a 4 Timer A4 one-shot pulse(1) INV14 bit in INVC1 register = 0 (Active Low) Dead time Values are transferred to the three-phase output shift register from registers IDB0 and IDB1 Rewrite registers IDB0 and IDB1 Upper arm (U-phase) output signal(1) Lower arm (U-phase) output signal(1) U-phase U-phase INV14 bit in INVC1 register = 1 (Active High) U-phase U-phase IR bit in the TB2IC register b 1 a 1 b 2 a 2 b 3 a 3 b 4 a 4 DU0 = 1 DU1 = 0 DUB1 = 1 DUB1 = 0 DUB0 = 0 DU0 = 1 DU1 = 1 Set to 0 by an interrupt request acknowledgement or by a program INV13 bit in the INVC1 register TA41 register b 5 NOTE: 1. Internal signals. See Three-Phase Motor Control Timer Function Block Diagram. The above applies under the following conditions: - INVC0 register: Bits INV01 and INV00 = 10b (ICTB2 counter is incremented by 1 at the rising edge of the timer A1 reload control signal) INV02 bit = 1 (Three-phase motor control timer function used) INV03 bit = 1 (Three-phase motor control timer output enabled) INV06 bit = 0 (Triangular wave modulation mode) - INVC1 register: INV10 bit = 0 (Timer B2 underflow) INV11 bit = 1 (Timer A11, A21, A41 used (Three-phase mode 1)) INV15 bit = 0 (Dead time enabled) INV16 bit = 1 (Rising edge of the three-phase output shift register (U-, V-, W-phase)) - ICTB2 register = 01h (First timer B2 interrupt occurs when timer B2 underflows for the first time, and the subsequent interrupts occur every second timer B2 underflow.) The following shows examples to change PWM output levels. - Default value of the timer: TA41 = b 1, TA4 = a1 (Registers TA4 and TA41 are rewritten every time the timer B2 interrupt occurs.) First time TA41 = b 2, TA4 = a2, second time TA41 = b3, TA4 = a3 - Default value of the registers IDB0 and IDB1: DU0 = 1, DUB0 = 0, DU1 = 0, and DUB1 = 1 They are changed to DU0 = 1, DUB0 = 0, DU1 = 1, and DUB1 = 0 at the third timer B2 interrupt. a 1 a 2 a 3 a 4 a 5 b 1 b 2 b 3 b 4 b 5 |
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |