| データシートサーチシステム |
|
B210LP データシート(PDF) 1 Page - Systemsensor advanced ideas. |
|
|
|||||||||||||||||||||||||||||
B210LP データシート(HTML) 1 Page - Systemsensor advanced ideas. |
|
1 / 2 page ![]() D250-01-00 1 I56-0595-007R B210LP Plug-in Detector Base INSTALLATION AND MAINTENANCE INSTRUCTIONS 3825 Ohio Avenue, St. Charles, Illinois 60174 1-800-SENSOR2, FAX: 630-377-6495 www.systemsensor.com BEfORE INSTALLINg Please thoroughly read the system wiring and installation manuals, and man- ual System Smoke Detectors Application Guide, which provides detailed in- formation on detector spacing, placement, zoning, and special applications. Copies of these manuals are available from System Sensor or through a Sys- tem Sensor distributor. gENERAL DESCRIPTION The B210LP is a plug in detector base intended for use in a 2-wire intelligent sys- tem, with screw terminals provided for power (+ and –), and remote annuncia- tor connections. Communication takes place over the power (+ and –) lines. BASE TERMINALS NO. FUNCTION 1 Power (–), Remote Annunciator (–) 2 Power (+) 3 Remote Annunciator (+) MOUNTINg This detector base mounts directly to 31/2- and 4-inch octagon boxes, 4-inch square boxes (with or without plaster rings) and single gang boxes. To mount, remove the decorative ring by turning it in either direction to unhook the snaps, then separate the ring from the base. Install the base on the box using the screws supplied with the junction box and the appropriate mounting slots in the base. Place the decorative ring on the base and rotate it in either direction until it snaps into place (see Figure 2). INSTALLATION WIRINg gUIDELINES All wiring must be installed in compliance with all applicable local codes and any special requirements of the authority having jurisdiction, using the proper wire size. The conductors used to connect smoke detectors to control panels and accessory devices should be color-coded to reduce the likelihood of wiring errors. Improper connections can prevent a system from responding properly in the event of a fire. For signal wiring (the wiring between interconnected detectors), it is recom- mended that the wire be no smaller than AWG 18. However, the screws and clamping plate in the base can accommodate wire sizes up to AWG 12. The use of twisted pair wiring or shielded cable for the power (+ and -) loop is recommended to minimize the effects of electrical interference. If shielded cable is used, the shield connection to and from the detector must be continuous by using wire nuts, crimping, or soldering, as appropriate for a reliable connection. Make electrical connections by stripping about 3/8 inch (10 mm) of insulation from the end of the wire (use strip gauge molded in base), sliding the bare end of the wire under the clamping plate, and tightening the clamping plate screw. Do not loop the wire under the clamping plate. The zone wiring of the detector base should be checked before the detector heads are installed in them. The wiring should be checked for continuity and polarity in the base, and dielectric tests should be performed. The base includes a label for recording the zone, address, and type of detector being installed. This information is important to set the address of the detector head that will later be plugged into the base and to verify the type required for that location. SPECIfICATIONS Diameter: 6.1 inches (155 mm) Mounting: 4-inch (102 mm) square box with or without plaster ring; Minimum Depth - 1.5 inches (38 mm) 4-inch Octagon Box; Minimum Depth - 1.5 inches (38 mm) 31/2-inch Octagon Box; Minimum Depth - 1.5 inches (38 mm) Single Gang Box; Minimum Depth - 1.5 inches (38 mm) Operating Temperature Range: Refer to applicable sensor Operating Temperature Range using the Base/Sensor Cross Reference Chart at http:\\www.systemsensor.com fIgURE 1. TERMINAL LAyOUT: 3 2 1 BASE TERMINALS TAMPER PROOF TAB C0127-00 fIgURE 2. MOUNTINg DETECTOR TO BOx: SNAP ON DECORATIVE RING SCREWS (NOT SUPPLIED) DETECTOR BASE BOX (NOT SUPPLIED) C0128-00 |
同様の部品番号 - B210LP |
|
同様の説明 - B210LP |
|
|
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |