| データシートサーチシステム |
|
CS5374 データシート(PDF) 29 Page - Cirrus Logic |
|
|
|||||||||||||||||||||||||||||
CS5374 データシート(HTML) 29 Page - Cirrus Logic |
|
29 / 44 page ![]() CS5374 CS5374 DS862F1 DS862F1 29 6. POWER MODES The CS5374 amplifiers and modulators have three power modes. Normal operation, power down with MCLK enabled, and power down with MCLK dis- abled. Power down mode is controlled by PWDN bits in the SPI registers, and are active high. When PWDN is enabled, internal circuitry is disabled, the analog inputs and outputs go high-impedance, and the de- vice enters a micro-power state. 6.1 Normal Operation With MCLK active and the amplifiers and modula- tors enabled (PWDN = 0) the CS5374 performs normal data acquisition. A differential analog input signal is converted to an oversampled 1-bit ΔΣ bit stream at 512 kHz. This ΔΣ bit stream is then digi- tally filtered and decimated by the CS5376A de- vice to a high-precision 24-bit output. 6.2 Power Down, MCLK Enabled With MCLK active and all amplifiers and modula- tors disabled (PWDN = 1) the CS5374 is placed into a power-down state. During this power-down state the amplifiers and modulators are disabled and all outputs are high impedance. In this mode power consumption is reduced, but not reduced as low as with MCLK inactive, as sections of the dig- ital state machine are kept awake to support SPI communications. Any unused amplifier/modulator channels can be turned off individually through the configuration registers. 6.3 Power Down, MCLK Disabled If MCLK is stopped, an internal loss-of-clock de- tection circuit automatically places the CS5374 into a power-down state. This power-down state is independent of the amplifier and modulator inter- nal configuration registers, and is automatically in- voked after approximately 40 μs without receiving an incoming MCLK edge. During this power-down state, the amplifiers and modulators are disabled and all outputs are high impedance. The entire digital state machine goes inactive but configuration register values are re- tained, with a reset required to clear them. When used with the CS5376A digital filter, the CS5374 is in this lowest power-down state immediately after reset since MCLK is disabled by default. NORMAL OPERATION MCLK = ON PWDN registers = disabled POWER DOWN MODE MCLK = ON PWDN registers = enabled POWER DOWN MODE MCLK = OFF PWDN registers = X Figure 17. Power Mode Diagram |
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |