2 / 4 page ![]() Only One Name Means ProTek’Tion™ www.protekdevices.com 05057.R5 2/11 Page 2 587B062LP - 587B302LP tyPicaL Device chaRacteRistics MaXiMuM Ratings @ 25°c unless otherwise specified PaRaMeteR syMBoL vaLue units Operating Line Voltage: +10% V O 240 Volts AC Line Current: 587B062LP/587B102LP/587B162LP/587B302LP - 6/10/16/30 Amps Peak Transient Voltage - 6000 Volts Peak Transient Current - 3000 Amps Current Leakage @ 240 Volts AC: Line-to-Neutral, Neutral-to-Ground, Line-to-Ground - 1 mA Operating Temperature - Note 1 T A -40 to 85 °C Storage Temperature - Note 1 T STG -40 to 85 °C notes 1. Measured at the center of the mounting surface. eLectRicaL chaRacteRistics @ 25°c unless otherwise specified PRotection MoDe (note 1) MaXiMuM cLaMPing voLtage (note 2) voLts oPen ciRcuit voLtage (note 2) @1.2/50µs voLts shoRt ciRcuit cuRRent (note 2) @ 8/20µs aMPs Line to Neutral 800 6000 3000 Neutral to Ground 1000 6000 3000 Line to Ground 1000 6000 3000 notes 1. Differential Mode Protection: Line to Neutral. Common Mode Protection: Line to Ground & Neutral to Ground. 2. Test condition responses to transient voltages. aRRestoR Definitions Clamping Voltage: The clamping voltage of an arrester is the voltage that appears across its terminals during conduction of a transient current. Standard Wave Form: The waveform of a surge current or voltage is designated by a combination of two numbers. The first number is for the time of the wave front expressed in microseconds from zero to the peak of the wave. The second number is for the time of the wavetail also expressed in microseconds from zero to the instant that the wavetail reaches one half of the crest or peak value, i.e., 8/20 µs waveform. Transient Current: The transient current of an arrestor is the peak surge current which flows through the arrester when voltage clamping occurs. oPeRation For maximum effectiveness, the protector should be installed directly after the AC line on/off switch and fuse. This will protect the electronics from the AC line switch arcing and the severe transients caused by a fuse clearing. Some heat is produced when operating at full current load, and heat sinking may be required to maintain case temperature below 85°C. The case temperature is measured at the center of the mounting surface. The unit should not be mounted to a low combusting temperature material such as wood. High energy transients will cause a large circulating current in the AC input line (2,500A is possible). To prevent electromagnetic coupling, the AC line on the input side of the protector must be dressed away from other wiring, magnetic shielding may be required. In addition, the electrical service must be connected to a low imped- ance earth ground. |
|
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |