Back Button ADP1853ACPZ-R7 Datasheet HTML 5Page - Analog Devices ADP1853ACPZ-R7 Datasheet HTML 6Page - Analog Devices ADP1853ACPZ-R7 Datasheet HTML 7Page - Analog Devices ADP1853ACPZ-R7 Datasheet HTML 8Page - Analog Devices ADP1853ACPZ-R7 Datasheet HTML 9Page - Analog Devices ADP1853ACPZ-R7 Datasheet HTML 10Page - Analog Devices ADP1853ACPZ-R7 Datasheet HTML 11Page - Analog Devices ADP1853ACPZ-R7 Datasheet HTML 12Page - Analog Devices ADP1853ACPZ-R7 Datasheet HTML 13Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 9 / 28 page
background image
Data Sheet
ADP1853
Rev. 0 | Page 9 of 28
Pin No.
Mnemonic
Description
17
PGOOD
Power Good. The open-drain power good indicator logic output with an internal 12.5 kΩ resistor is connected
between PGOOD and VCCO. PGOOD is pulled to ground when the output is outside the regulation window. An
external pull-up resistor is not required. If the controller is configured as a slave in the interleaved dual-phase
application by tying the FB pin high to VCCO, the pulse skip mode is enabled by driving the PGOOD pin low
externally in cases when the master is in pulse skip mode at light loads. Otherwise, if the master is configured to
forced PWM operation, PGOOD of the slave controller must be connected to the PGOOD of the master.
18
RAMP
Programmable Current Setting for Slope Compensation. Connect a resistor from RAMP to V
IN. The voltage at RAMP
is 0.2 V during operation. This pin is high impedance when the channel is disabled.
19
FREQ
Internal Oscillator Frequency, f
OSC. Sets the desired operating frequency between 200 kHz and 1.5 MHz with one
resistor between FREQ and AGND. Connect FREQ to AGND for a preprogrammed 300 kHz or tie FREQ to VCCO for
600 kHz operating frequency.
20
TRK
Tracking Input. Connect TRK to VCCO if tracking is not used.
EPAD
Exposed Pad. Connect the bottom of the exposed pad to the system AGND plane.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28


データシート ダウンロード

Go To PDF Page


リンク URL



ALLDATASHEETはお客様のビジネスに役立ちますか?  [ DONATE ] 

Alldatasheetは   |   広告   |   お問い合わせ   |   プライバシーポリシー   |   データシートへのリンク    |   リンク交換   |   メーカーリスト
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com