| データシートサーチシステム |
|
POWRBUSBAR データシート(PDF) 1 Page - Littelfuse |
|
|
|||||||||||||||||||||||||||||
POWRBUSBAR データシート(HTML) 1 Page - Littelfuse |
|
|
1 / 1 page ![]() © January 2012 Littelfuse POWR-GARD Products www.littelfuse.com POWR-GARD® POWR-SAFE Dead Front Holders Bus Bar 1 Specifications Voltage Ratings: 600 VAC/DC 1000 VDC* Current Ratings: SCCR: 10 kA, 100 kA** Conductor: Copper Pitch: 17.8 mm Approvals: UL508 File E328654 Environmentals: RoHS Compliant and Pb free End caps are standard with all 3 phase configurations except 57-pole meter length. End caps aren’t needed for the 1 phase configurations from the factory or if the copper bus is trimmed per the supplied instructions. Power feed lugs and protective covers are extra. bus bar system POWR Distribution 3 PHase, 25 mm2 LeNGtH (mm) system Number PoLes 3PH6P25mm 6 104 3PH9P25mm 9 158 3PH12P25mm 12 214 3PH15P25mm 15 266 3PH57P25mm 57 1009 Endcaps Part Number: EDCP42 for Single Phase 50 piece bag Part Number: EDCP7 for Three Phase 50 piece bag Description A key objective for panel designers is safe distribution of power to multiple fuseholders in a compact design. The Littelfuse UL508 bus bar system eliminates most wire terminations in a timesaving package. A power distribution block and associated conductors are no longer needed to feed multiple POWR-SAFE fuseholders. Features/Benefits • Touch-safe design offers protection when replacing fuses • Compact design • 35 mm DIN Rail Mountable • Available in one and three phase configurations • No fuse pullers or tools required for fuse removal • RoHS Compliant and Pb free • Can be cut down to optimal size Recommended Fuseholders LPSM (600 V) LPSC (600 V) LPHV (1000 V) Web Resources Downloadable CAD drawings and other technical information: www.littelfuse.com/busbar Accessories *1 Phase 18 mm2 rated 1000 VDC up to 160 A when center fed 1 Phase 25 mm2 rated 1000 VDC up to 200 A when center fed **When protected directly upstream by Class J 175 amperes max (18 mm2 bus bar) and Class J 200 amperes max (25 mm2 bus bar). Ordering Information 1 PHase, 18 mm2 LeNGtH (mm) system Number PoLes 1PH3P18mm 3 50 1PH6P18mm 6 104 1PH9P18mm 9 155 1PH12P18mm 12 208 1PH15P18mm 15 270 1PH57P18mm 57 1009 1 PHase, 25 mm2 LeNGtH (mm) system Number PoLes 1PH3P25mm 3 50 1PH6P25mm 6 104 1PH9P25mm 9 155 1PH12P25mm 12 208 1PH15P25 15 270 1PH57P25mm 57 1009 3 PHase, 18 mm2 LeNGtH (mm) system Number PoLes 3PH6P18mm 6 104 3PH9P18mm 9 158 3PH12P18mm 12 214 3PH15P18mm 15 266 3PH57P18mm 57 1009 Pole Protective Covers Part Number: CTPT5 5 covers Power Feed Lug Part Number: BB18 Ampere Rating: 115 A Wire: #10 – 1/0 AWG copper Torque: 50 lb-in Cross seCtioN (mm2) 18 mm2 25 mm2 END FED 80 A 100 A CENTER FED 160 A 200 A |
同様の部品番号 - POWRBUSBAR |
|
同様の説明 - POWRBUSBAR |
|
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |