| データシートサーチシステム |
|
ART2812TCKA データシート(PDF) 5 Page - International Rectifier |
|
|
|||||||||||||||||||||||||||||
ART2812TCKA データシート(HTML) 5 Page - International Rectifier |
|
5 / 12 page ![]() www.irf.com 5 ART28XXT SERIES Radiation Performance The radiation tolerance characteristics inherent in the ART28XXT converter are the direct result of a carefully planned ground-up design program with specific radiation design goals. After identification of the general circuit topology, a primary task of the design effort was selection of appropriate elements from the list of devices for which extensive radiation effects data was available. By imposing sufficiently large margins on those electrical parameters subject to the degrading effects of radiation, designers were able to select appropriate elements for incorporation into the circuit. Known radiation data was utilized for input to PSPICE and RadSPICE in the generation of circuit performance verification analyses. Thus, electrical performance capability under all environmental conditions including radiation was well understood before first application of power to the inputs. A principal design goal was a converter topology that, because of large design margins, had radiation performance essentially independent of normal elemental lot radiation Completion of first article fabrication, screening and standard environmental testing was followed by radiation testing to confirm design goals. All design goals were met handily and in most cases exceeded by large margin. These test samples were built with elements that, with the foregoing exceptions, were not screened for radiation characteristics. Additional radiation tests on subsequent ART28XXT manufacturing lots provide continued confirmation of the soundness of the design goals as well as justification for the element selection criteria. The following table specifies guaranteed minimum radiation exposure levels tolerated while maintaining specification limits. performance variations. In the few instances where such margins were not assured, element lots were selected from which die were fabricated (and characterized) as radiation hard devices so that realization of the design goals could be assured. Inspection Application Quantity Group A Part of Screening on Each Unit 100% Group B Each Inspection Lot 5 units Group C First Inspection Lot or Following Class 1 Change 10 Units Group D In Line (Part of Element Evaluation) Standard Periodic Inspections on ART28XXT Series As prescribed by MIL-PRF-38534 for Option 2 Radiation Performance Characteristics International Rectifier currently does not have a DLA Land and Maritime certified Radiation Hardness Assurance Program. Test Inspection Method Min Typ Unit MIL-PRF-883, Method 1019 Total Ionizing Dose (Gamma) Operating bias applied during exposure, Full Rated Load, VIN = 28V 200 300 Krads(Si) Dose Rate (Gamma Dot) MIL-STD-883, Method 1023 Temporary Saturation Operating bias applied during exposure, 1E8 Rads(Si)/sec Survival Full Rated Load, VIN = 28V 4E10 1E11 Neutron Fluence MIL-STD-883, Method 1017 8E12 1E13 Neutrons/cm 2 Heavy Ions (LET) Single Event Effects Operating bias applied during exposure, SEU, SEL, SEGR, SEB Full Rated Load, VIN = 28V 83 MeVxcm 2 /mg Test lab: Brookhaven National Laboratory, Tandem Van de Graaff Generator |
|
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |