| データシートサーチシステム |
|
GMS81608K データシート(PDF) 46 Page - Hynix Semiconductor |
|
|
|||||||||||||||||||||||||||||
GMS81608K データシート(HTML) 46 Page - Hynix Semiconductor |
|
46 / 79 page ![]() STOP MODE For applications where power consumption is a critical factor, device provides reduced power of STOP. An instruction that STOP causes that to be the last instruction executed before going into the Stop mode. In the Stop mode, the on-chip oscillator is stopped. With the clock frozen, all functions are stopped, but the on-chip RAM and Control registers are held. The port pins out the values held by their respective port data register Rx, port direction register RxDD. The status of peripherals during Stop mode is shown below. Peripheral Status RAM Retain Control registers Retain I/O Retain Oscillation Stop XIN Low X OUT High In the Stop mode of operation, VDD can be reduced to minimize power consumption. Care must be taken, however, to ensure that VDD is not reduced before the Stop mode is invoked, and that VDD is restored to its normal operating level, before the Stop mode is termi- nated. The reset should not be activated before VDD is restored to its normal operating level, and must be held active long enough to allow the oscillator to restart and stabilize (minimum 20 msec). Caution: The NOP instruction have to be written more than two to next line of the STOP instruction. Ex) STOP NOP NOP Release Stop Mode The exit from Stop mode is hardware reset or external interrupt. Reset redefines all the Control registers but does not change the on-chip RAM. External interrupts allow both on-chip RAM and Control registers to retain their values. If I-flag = 1, the normal interrupt response takes place. If I-flag = 0, the chip will resume execution starting with the instruction following the STOP instruction. It will not vector to interrupt service routine. When exit from Stop mode by external interrupt from Stop mode, enough oscillation stabilization time is required to normal operation. Figure 37 shows the timing diagram. When release the Stop mode, the EXTERNAL INTERRUPT INTERNAL CLOCK OSCILLATOR tST > 20 ms NORMAL OPERATION BASIC INTERVAL TIMER COUNTER CLEAR BASIC INTERVAL TIMER N+2 00 01 FE FF 00 N N+1 STABILIZATION TIME 01 02 03 NORMAL OPERATION STOP MODE STOP INSTRUCTION EXECUTION Figure 37. Timing of Stop Release by External Interrupt GMS81604/08 LG Semicon 42 |
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |