13 / 25 page ![]() AN2269 - Application Note Emergency Deactivation/Fault Detection 13/25 3.4 VCC Short Circuit Fault Protection The ST8024 is able to supply the card with current pulses of about 140mA for no longer than 5.5µs, typical (see Figure 11 and Figure 12 on page 14). Short circuit protection is an important interface feature that warns the sequencer block if the output current becomes higher than the short circuit current limit ( ≈120mA) for too much time. This characteristic allows the device to supply the card with current pulses higher than the maximum allowed, if their lengths are not too long. If the current pulses last for more than 5.5µs, the deactivation sequence starts to protect the card. The OFF pin goes low so as to warn the microcontroller about the overcurrent fault. The sequence in Figure 12 on page 14 shows how the current pulse becomes long enough to make the short circuit protection happen. Figure 11. ST8024 Current Supply Sequence Legend: 1. CH1 = CMDVcc 2. CH2 = ISC Pulse 3. CH3 = VCC 4. CH4 = OFF |
|
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|