| データシートサーチシステム |
|
AN4241 データシート(PDF) 13 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
AN4241 データシート(HTML) 13 Page - STMicroelectronics |
|
13 / 18 page ![]() AN4241 Protections Doc ID 024193 Rev 1 13/18 At power-up, the device is in undervoltage status: the power bridges of the device are kept disabled until the supply voltage is below the turn-on threshold. In this condition all the commands enabling the bridges (e.g. Move, Run, GoTo, HardStop, etc.) are ignored and the UVLO failure flag is forced low. When the turn-on threshold is reached the power bridges are operative. The UVLO flag is kept low until it is released through a GetStatus command. The device returns in undervoltage status if the supply voltage falls below the turn-off threshold. Figure 8. Undervoltage protection Turn-on threshold VS Time Power bridges are kept disabled. to zero. Power bridges are kept disabled. Power bridges can be enabled. it is released (GetStatus command). Power bridges can be enabled. it is released (GetStatus command). Turn-off threshold the UVLO flag is forced to zero. the UVLO flag is forced The UVLO flag is kept to zero until The UVLO flag is kept to zero until AM16594v1 |
|
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|