14 / 19 page ![]() High speed internal oscillator trimming AN2822 14/19 Doc ID 14983 Rev 2 The combined standard uncertainty of the HSI frequency measurement is evaluated bellow. Comparing the first and second terms we can find that a contribution caused by uncertainty, u(NHSI), is negligible and can be omitted. This statement is valid if the calibration frequency is well below the HSI frequency. Let’s evaluate the uncertainty caused by the finite regulation steps. Finally, the total combined uncertainty of the HSI frequency is evaluated bellow. Assuming that the required confidence level is 95% using the coverage factor k=2, we can express the extended uncertainty, U, as following. c f cal f cal ∂ ∂f HSIm N HSI L ------------- 320 10 ⋅ 3 468.7 8.376 10 9 ⋅ () ≅ == u c 2 f HSIm () c N HSI 2 u 2 N HSI () c f cal 2 u 2 f cal () + 468.7 8.376 10 9 ⋅ + ≅ = u c fHSIm () 91.52 kHz ≅ uf trim () 160 10 3 ⋅ 23 -------------------------- 46.19 kHz ≅ = uf HSI () u 2 f trim () u c 2 f HSIm () + 102.5 kHz ≅ = Uk u f HSI () ⋅ 2 102.5 kHz 205 kHz ≅ ⋅ ≅ = |
|
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|