Back Button MIC2025 Datasheet HTML 6Page - Micrel Semiconductor MIC2025 Datasheet HTML 7Page - Micrel Semiconductor MIC2025 Datasheet HTML 8Page - Micrel Semiconductor MIC2025 Datasheet HTML 9Page - Micrel Semiconductor MIC2025 Datasheet HTML 10Page - Micrel Semiconductor MIC2025 Datasheet HTML 11Page - Micrel Semiconductor MIC2025 Datasheet HTML 12Page - Micrel Semiconductor MIC2025 Datasheet HTML 13Page - Micrel Semiconductor MIC2025 Datasheet HTML 14Page - Micrel Semiconductor Next Button
Zoom Inzoom in Zoom Outzoom out
 10 / 16 page
background image
MIC2025/2075
Micrel
MIC2025/2075
10
March 2000
Short-Circuit Applied to Enabled Output
When a heavy load or short-circuit is applied, a large transient
current may flow until the current-limit circuitry responds.
Once this occurs the device limits current to less than the
short-circuit current limit specification. See the Short-Circuit
Transient Response graph under Functional Characteristics.
Current-Limit Response—Ramped Load
The MIC2025/75 current-limit profile exhibits a small foldback
effect of about 200mA. Once this current-limit threshold is
exceeded the device switches into a constant current mode.
It is important to note that the device will supply current until
the current-limit threshold is exceeded. See the Current-Limit
Response graph under Functional Characteristics.
Fault Flag
The FLG signal is an N-channel open-drain MOSFET output.
FLG is asserted (active-low) when either an overcurrent or
thermal shutdown condition occurs. In the case where an
overcurrent condition occurs, FLG will be asserted only after
the flag response delay time, t
D, has elapsed. This ensures
that FLG is asserted only upon valid overcurrent conditions
and that erroneous error reporting is eliminated. For ex-
ample, false overcurrent conditions can occur during hot-plug
events when a highly capacitive load is connected and
causes a high transient inrush current that exceeds the
current-limit threshold. The FLG response delay time t
D is
typically 3ms.
Undervoltage Lockout
Undervoltage lockout (UVLO) prevents the output MOSFET
from turning on until V
IN exceeds approximately 2.5V. Under-
voltage detection functions only when the switch is enabled.
VEN
VOUT
IOUT
Short-Circuit Fault
Thermal Shutdown
Reached
Load Removed
(Output Reset)
VFLG
ILIMIT
IDC
tD
Figure 1. MIC2075-2 Timing: Output Reset by Removing Load
VEN
VOUT
IOUT
Short-Circuit Fault
Thermal Shutdown
Reached
Load/Fault
Removed
VFLG
IDC
ILIMIT
tD
Figure 2. MIC2025-2 Timing



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16


データシート ダウンロード

Go To PDF Page


リンク URL



ALLDATASHEETはお客様のビジネスに役立ちますか?  [ DONATE ] 

Alldatasheetは   |   広告   |   お問い合わせ   |   プライバシーポリシー   |   データシートへのリンク    |   リンク交換   |   メーカーリスト
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com