37 / 38 page ![]() LC79451KB No.A2223-37/38 10-3. Power Supply OFF Sequence When you turn off VDD power supply, the discharge of a stored electric charge is recommended. This is because image may change when an electric charge is left in the external capacitor of VOUT2 and VOUT3. You can discharge a stored electric charge in the following procedures when you cannot meet a condition of Cf.6-6. (1) Operate charge-pump if VOUT0 < 2.0V or VOUT1 < 4.0V. (2) Stop charge-pump. (3) Operate discharge. (control register 2: DISCON = 1) (4) Turn off VDD power supply. You can maintain a discharge state when you turn off VDD power supply during discharge operation as RESET = VDD. 10-4. Parasitic Circuit between Charge-pump Pins and Power Supply Pins Between charge-pump pins and power supply pins, parasitic diode is connected equivalently to constitute a circuit. Fig.19. Parasitic circuit diagram between pin VOUT2 (+15V) VOUT1 (+5V) VOUT0 (+2.5V) VSS (0V) VOUT3 (-15V) VDD2 (+1.8V to +3.6V) VDD (+1.6V to +3.6V) |
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|