| データシートサーチシステム |
|
AD7616BSTZ データシート(PDF) 39 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD7616BSTZ データシート(HTML) 39 Page - Analog Devices |
|
39 / 51 page ![]() AD7616 Data Sheet Rev. 0 | Page 38 of 50 DIAGNOSTICS DIAGNOSTIC CHANNELS In addition to the 16 analog inputs, VxA and VxB, the AD7616 can also convert the following diagnostic channels: VCC and the analog ALDO voltage. The diagnostic channels are selected for conversion by programming the channel register (see the Channel Register section) to the corresponding channel identifier. Diagnos- tic channels can also be added to the sequencer stack in software mode, but only provide an accurate reading at throughput rates <250 kSPS. See Figure 65 for a plot of the deviation from expected value vs. sampling frequency that can be expected when using the diagnostic channels. The expected output for each channel is governed by the following transfer functions: ( ) ( ) REF REF CC CC V V V Code V × × × = 5 768 , 32 – 4 ( ) ( ) ( ) REF REF ALDO V V V Code LDO × × × × = 10 768 , 32 7 – 10 Figure 65. Deviation from Expected Value vs. Sampling Frequency Figure 66. VCC Diagnostic Transfer Function Figure 67. ALDO Diagnostic Transfer Function INTERFACE SELF TEST It is possible to test the integrity of the digital interface by selecting the communication self test channel in the channel register (see the Channel Register section). Selecting the communication self test for conversion forces the conversion result register to a known fixed output. When conversion code is read, Code 0xAAAA is output as the conversion code of ADC A, and Code 0x5555 is output as the conversion code of ADC B. CRC The AD7616 has a cyclic redundancy check (CRC) checksum mode to improve interface robustness by detecting errors in data. The CRC feature is available in both software (serial and parallel) mode and hardware (serial only) mode. The CRC feature is not available in hardware parallel mode. The CRC result is contained within the status register. Enabling the CRC feature enables the status register and vice versa. In hardware mode, the CRCEN pin controls the CRC feature. The CRC feature is enabled or disabled when the AD7616 is released from full reset. The logic level of the CRCEN pin when the RESET pin is released determines whether the CRC feature is enabled or disabled. Set the CRCEN pin to 1 to enable the CRC feature. After the RESET pin is released, the function is fixed and a full reset via the RESET pin is required to exit the function and set up an alternative configuration. See the Reset Functionality section for additional information. After being enabled, the CRC result is appended to the conversion result and consists of a 16-bit word, where the first eight bits contain the channel ID of the last channel pair converted and the last eight bits are the CRC result. The result is accessed via an extra read command, as shown in Figure 68. In software mode, the CRC function is enabled by setting either the CRCEN bit or the STATUSEN bit in the configuration register to 1 (see the section). 750 –750 –500 –250 0 250 500 0 600 500 400 300 200 100 SAMPLING FREQUENCY (kSPS) ALDO ERROR VCC ERROR 29000 22000 23000 24500 26000 28000 25000 27000 4.50 4.75 5.00 5.50 5.25 VCC (V) –9000 –8800 –8600 –8400 –8200 –8000 –7800 –7600 –7400 –7200 1.75 1.80 1.85 1.90 1.95 ALDO (V) |
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |