2 / 5 page ![]() DC/DC Converter MED-2 REV.: 06/2016 www.recom-power.com BASIC CHARACTERISTICS Parameter Condition Min. Typ. Max. Absolute Maximum Input Voltage ( 3sec max.) 2:1 5Vin nom. 12Vin nom. 24Vin nom. 48Vin nom. 16VDC 25VDC 50VDC 100VDC 4:1 24Vin nom. 48Vin nom. 50VDC 100VDC Under Voltage Lockout 2:1 5Vin nom. 12Vin nom. 24Vin nom. 48Vin nom. 4VDC 8VDC 16VDC 33VDC 4.5VDC 9VDC 18VDC 36VDC 4:1 24Vin nom. 48Vin nom. 8VDC 16VDC 9VDC 18VDC Start-up Time constant resistive load, Power up or Remote ON/OFF 30ms Remote ON/OFF (referenced to -Vin Pin) DC-DC ON DC-DC OFF Open or 0-1.2VDC 2.2-12VDC Current of CTRL Pin -0.5mA 1mA Remote OFF Input Current 2.5mA Internal Operating Frequency 135kHz 150kHz 165kHz Output Ripple and Noise (20MHz BW limited) 10µF/25V X7R MLCC for 3.3, 5Vout 10µF/25V X7R MLCC for 12, 15Vout 4.7µF/50V X7R MLCC for 24Vout 30mVp-p 40mVp-p 50mVp-p Calculation Example: Vin = 12V Iout = 50% Eff 100% = 87.5% Eff factor50% = 0.98 R th = 18°C/W T CASEmax = 105°C T AMBmax = T CASEmax - TOVER = 105 - 4.5 = 100.5°C T OVER = R th * PDIS50% = 18 * 0.25 = 4.5°C P DIS50% = P in50% - P out50% = P out100% * 0.5 - (P out100% * 0.5) = 1.75 - 1.5 = 0.25W Eff 50% Eff 50% = Eff 100% * Efffactor50% = 87.5 * 0.98 = 85.75% Graph1: Efficiency Factor vs. Load Load [%] 10 0 20 30 40 50 60 70 80 90 100 0.0 0.2 0.4 0.6 0.8 1.2 1.0 Efficiency Crosstable [%] @ full load Input Voltage 5 12 24 48 24W 48W 3.3S 81 82 82 81 82 81 05S 84.5 84.5 84.5 84 84.5 84 12S 85.5 87 87 87 87 87 15S 87.5 87 87 86.5 87 86.5 24S 85.5 87 87 86.5 87 86.5 05D 83 83.5 83 83 83 83 12D 86 87.5 86 86 87 86 15D 86 86.5 86 86 86 86 Table1: Efficiency Crosstable Efficiency REM3 Series Specifications (measured @ ta= 25°C, nominal input voltage, full load and after warm-up) 10 20 30 40 50 60 70 80 90 100 Load [%] 50 60 70 80 90 100 choose your model: REM3-1212D • Efficiency from Table1 (= 87.5% @ max Load / nom Vin) • Loading conditions in application (e.g. 50%) • use Eff factor from Graph1 (= 0.98 @50%) Calculation: |
|
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |