| データシートサーチシステム |
|
PSLS05C データシート(PDF) 6 Page - Wall Industries,Inc. |
|
|
|||||||||||||||||||||||||||||
PSLS05C データシート(HTML) 6 Page - Wall Industries,Inc. |
|
6 / 7 page ![]() Rev A PSLS05C SERIES 5 Watts AC/DC Converter Single Output 11/4/2016 Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797 website: www.wallindustries.com • e-mail: sales@wallindustries.com Page 6 of 7 EMC RECOMMNEDED CIRCUIT Figure 3: Recommended circuit for applications which require higher EMC standard. EMC RECOMMNEDED CIRCUIT PCB LAYOUT Figure 4: EMC application circuit PCB layout Safety and Recommended Wiring: linewidth ≥3mm, line-line distance≥6mm, line-ground distance ≥6mm, A≥6.4mm EXTERNAL CIRCUIT PARAMETERS Model C1 (Required) C2 (Required) L1 (Required) C3 (Required) CX1 C4 CY0 FUSE (Required) TVS PSLS05C-15B03S(-F) 22µF/400V 470µF/10V 0.47uH 150µF/35V 0.1µF/275VAC 100nF/50V 1nF/400 VAC 1A/250V SMBJ7.0A PSLS05C-15B05S(-F) 470µF/16V PSLS05C-15B09S(-F) 300µF/25V 1uH 150µF/35V SMBJ12A PSLS05C-15B12S(-F) SMBJ20A PSLS05C-15B15S(-F) PSLS05C-15B24S(-F) 100µF/35V 4.7uH 47µF SMBJ30A Notes: 1. C1, C2, and C3 are electrolytic capacitors. They are required for both AC input and DC input, When AC input, C1 is used as filter capacitor, the value of C1 is recommended to be 22µF/400V. When DC input, C1 is used as EMC filter capacitor, the value of C1 is recommended to be 10µF/400V (when the input voltage is above 370VDC, the recommended value of C1 is 10µF/450V). C2 and C3 are output filer capacitors, they are recommended to be high frequency and low impedance electrolytic capacitors. Capacitance and rated ripple current of capacitors refer to the datasheets provided. Voltage derating of capacitors should be 80% or above. C4 is a ceramic capacitor, which is used to filter high frequency noise. C2, C3 and L1 form a pi-type filter circuit. Current of L1 refer to the datasheets provided by the manufacturers, current derating should be 80% or above. To protect post-circuits (if converter fails), TVS is recommended. External NTC thermistor is recommended to be 5D-9. External input MOV is recommended to use S14K350. 2. For Standard EMC requirement, please refer to figure 1. If higher EMC requirement, please refer to figure 3, recommended parameters are shown in table below. Recommended Parameter for Higher EMC Standard Circuit Components Recommend Parameter MOV2 S10K300 CY1, CY2 1nF/400VAC CX 0.1µF/275VAC LCM 3.5mH LDM 5mH FC-L01DV1 1KV/2KV Surge Protector FUSE 1A/250V, slow blow, it must be connected to FUSE |
|
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |